Approaches to eliminate near field artifact of MURA

  • Since the Coded Aperture technique has been successfully applied on X-ray imaging space telescopes, most attention of its development has turned to its application in medical imaging, for it has a very tempting quality to greatly inhance the detect sensitivity without gravely lower the spacial resolution. Now the artifacts of the coded aperture to image a radioactive object nearby comes up as an problem, and among types of coded apertures the MURA[1] is one of the most discussed. Roberto Arrcosi came up with the solution to remove the artifacts utilising mask and antimask. In this article we present two ways to eliminate the second order aberration based on his works.
  • 加载中
  • [1] . Gal O, Gmar M, Ivanov O P et al. Nucl. Instrum. Methods,A, to be published2. Woodring M, Beddingfield D, Souza D et al. Nucl. Instrum.Methods, 2003, A505: 415-4193. Gottesman S R, Fenimore E E. Appl. Opt., 1989, 28: 43444. Accorsi R, Gasparini F, Lanza R C. Nucl. Instrum. Methods, 2001, A474: 273-2845. Accorsi R, Lanza R C. Appl. Opt., 2001, 40: 4697-47056. Shepp L, Vardi Y. IEEE Trans. Med. Imag., 1982, 1: 113-1227. Parra L, Barrett H H. IEEE Trans. Med. Imag., 1998,17(2): 228-2358. Wilson D W, Barrett H H, Clarkson E W. IEEE Trans. Med. Imag., 2000, 19(5): 412-4229. Clarkson E, Barrett H H, Wilson D W. Proc. SPIE, 1998,3336: 251-25910. Clarkson E, Wilson D W, Barrett H H. Proc. SPIE, 1999,3659: 107-11711. Fenimore E E, Cannon T M. Appl. Opt., 1981, 20: 1858-1864
  • 加载中

Get Citation
Approaches to eliminate near field artifact of MURA[J]. Chinese Physics C, 2008, 32(1): 80-82. doi: 10.1088/1674-1137/32/1/018
Approaches to eliminate near field artifact of MURA[J]. Chinese Physics C, 2008, 32(1): 80-82.  doi: 10.1088/1674-1137/32/1/018 shu
Milestone
Received: 2006-12-22
Revised: 2007-09-03
Article Metric

Article Views(3927)
PDF Downloads(781)
Cited by(0)
Policy on re-use
To reuse of subscription content published by CPC, the users need to request permission from CPC, unless the content was published under an Open Access license which automatically permits that type of reuse.
通讯作者: 陈斌, bchen63@163.com
  • 1. 

    沈阳化工大学材料科学与工程学院 沈阳 110142

  1. 本站搜索
  2. 百度学术搜索
  3. 万方数据库搜索
  4. CNKI搜索

Email This Article

Title:
Email:

Approaches to eliminate near field artifact of MURA

    Corresponding author: ,

Abstract: Since the Coded Aperture technique has been successfully applied on X-ray imaging space telescopes, most attention of its development has turned to its application in medical imaging, for it has a very tempting quality to greatly inhance the detect sensitivity without gravely lower the spacial resolution. Now the artifacts of the coded aperture to image a radioactive object nearby comes up as an problem, and among types of coded apertures the MURA[1] is one of the most discussed. Roberto Arrcosi came up with the solution to remove the artifacts utilising mask and antimask. In this article we present two ways to eliminate the second order aberration based on his works.