×
近期发现有不法分子冒充我刊与作者联系,借此进行欺诈等不法行为,请广大作者加以鉴别,如遇诈骗行为,请第一时间与我刊编辑部联系确认(《中国物理C》(英文)编辑部电话:010-88235947,010-88236950),并作报警处理。
本刊再次郑重声明:
(1)本刊官方网址为cpc.ihep.ac.cn和https://iopscience.iop.org/journal/1674-1137
(2)本刊采编系统作者中心是投稿的唯一路径,该系统为ScholarOne远程稿件采编系统,仅在本刊投稿网网址(https://mc03.manuscriptcentral.com/cpc)设有登录入口。本刊不接受其他方式的投稿,如打印稿投稿、E-mail信箱投稿等,若以此种方式接收投稿均为假冒。
(3)所有投稿均需经过严格的同行评议、编辑加工后方可发表,本刊不存在所谓的“编辑部内部征稿”。如果有人以“编辑部内部人员”名义帮助作者发稿,并收取发表费用,均为假冒。
                  
《中国物理C》(英文)编辑部
2024年10月30日

Time-like proton form factor measurement with PANDA

Get Citation
M. Sudol (for \=PANDA collaboration). Time-like proton form factor measurement with PANDA[J]. Chinese Physics C, 2009, 33(12): 1244-1248. doi: 10.1088/1674-1137/33/12/031
M. Sudol (for \=PANDA collaboration). Time-like proton form factor measurement with PANDA[J]. Chinese Physics C, 2009, 33(12): 1244-1248.  doi: 10.1088/1674-1137/33/12/031 shu
Milestone
Received: 2009-08-07
Revised: 1900-01-01
Article Metric

Article Views(2737)
PDF Downloads(578)
Cited by(0)
Policy on re-use
To reuse of subscription content published by CPC, the users need to request permission from CPC, unless the content was published under an Open Access license which automatically permits that type of reuse.
通讯作者: 陈斌, bchen63@163.com
  • 1. 

    沈阳化工大学材料科学与工程学院 沈阳 110142

  1. 本站搜索
  2. 百度学术搜索
  3. 万方数据库搜索
  4. CNKI搜索

Email This Article

Title:
Email:

Time-like proton form factor measurement with PANDA

  • (Institut de Physique Nucléaire, CNRS/IN2P3, Université Paris Sud, Orsay, France)

Abstract: 

The electromagnetic probe is an excellent tool to investigate the structure of the nucleon. The nearly 4π detector PANDA, will allow to make a precise determination of the electromagnetic form factors of the proton in the time-like region with unprecedented precision. In the one-photon exchange approximation, the center of mass unpolarized differential cross section of the reaction pp→e+e is a linear combination of the squared moduli of the electric GE and magnetic GM proton form factors. The precise measurement of the angular distribution over almost full angular range then directly gives these quantities. At present only two experiments have provided the ratio R=|GE|/|GM| but with large statistical uncertainties. It is shown that with strict PID cuts and a kinematic fit, the dominant background, pp→π+π, can be supressed to much less than 1 % of the signal, without affecting the extraction of the ratio R. PANDA will therefore offer a unique opportunity to measure the ratio with a precision ranging from <1% at low q2 up to 30% for q2 = 14 (GeV/c)2.

    HTML

目录

/

DownLoad:  Full-Size Img  PowerPoint
Return
Return