×
近期发现有不法分子冒充我刊与作者联系,借此进行欺诈等不法行为,请广大作者加以鉴别,如遇诈骗行为,请第一时间与我刊编辑部联系确认(《中国物理C》(英文)编辑部电话:010-88235947,010-88236950),并作报警处理。
本刊再次郑重声明:
(1)本刊官方网址为cpc.ihep.ac.cn和https://iopscience.iop.org/journal/1674-1137
(2)本刊采编系统作者中心是投稿的唯一路径,该系统为ScholarOne远程稿件采编系统,仅在本刊投稿网网址(https://mc03.manuscriptcentral.com/cpc)设有登录入口。本刊不接受其他方式的投稿,如打印稿投稿、E-mail信箱投稿等,若以此种方式接收投稿均为假冒。
(3)所有投稿均需经过严格的同行评议、编辑加工后方可发表,本刊不存在所谓的“编辑部内部征稿”。如果有人以“编辑部内部人员”名义帮助作者发稿,并收取发表费用,均为假冒。
                  
《中国物理C》(英文)编辑部
2024年10月30日
  • A proton therapy facility based on a linac injector and a slow-cycling synchrotron is proposed. To obtain good treatments for different cancer types, both the spot scanning method and the double-scattering method are adopted in the facility, whereas the nozzles include both gantry and fixed beam types. The proton accelerator chain includes a synchrotron of 250 MeV in maximum energy, an injector of 7 MeV consisting of an RFQ and a DTL linac, with a repetition rate of 0.5 Hz. The slow extraction using the third-order resonance and together with the RFKO method is considered to be a good method to obtain a stable and more-or-less homogenous beam spill. To benefit the spot scanning method, the extraction energy can be as many as about 200 between 60 MeV and 230 MeV. A new method—the emittance balancing technique of using a solenoid or a quadrupole rotator is proposed to solve the problem of unequal emittance in the two transverse planes with a beam slowly extracted from a synchrotron. The facility has been designed to keep the potential to be upgraded to include the carbon therapy in the future.

  • 加载中
  • [1] . ZHOU L N, ZHANG M, LUO Z et al. HEP NP, 1998,22(11): 1042-1049 (in Chinese)2. FANG Shou-Xian, WEI Jie, FU Shi-Nian. The Conceptual Design of a Proton Rapid Cycling Medical Synchrotronfor Therapy. Proc. of 18th Int. Collaboration on Advanced Neutron Sources. Dongguan, April 2007: 692-7003. APTF Conceptual Design Report, IHEP-AC-IP-Note/2009-014. Abe M. Charged Particle Radiotherapy at the Hyogo Ion Beam Medical Center: Characteristics, Technology andClinical Results. Proc. of Japan Acad., 2007, Ser. B, 83:151-1635. Haberer T, Becher W, Schardt D, Kraft G. Nucl. Instrum.Methods in Phys. Res. A, 1993, 330: 296-3146. Pedroni E, Bacher R, Blattmann H et al. Medical Physics,1995, 22(1): 37-537. Yonai S, Kanematsu N, Komori M et al. Med. Phys., 2008,35(3): 927-9388. Slater J M, Archambeau J O, Miller D W et al. Int. J. Radn Oncology Biol. Phys., 1991, 22: 3839. Hiramoto K, Umezawa M, Saito K et al. Nucl. Instrum.Methods in Phys. Res. B, 2007, 261: 786-79010. Jongen Y, Kleeven W, Zaremba S. New Cyclotron Developments at IBA. Proc. of 17th Int. Conf. on Cyclotrons and Their Appl. Tokyo, 2004. 110-11411. Geisler A, Baumgarten C, Hobl A et al. Status report of the ACCEL 250 MeV Medical Cyclotron. Proc. of 17th Int.Conf. on Cyclotrons and Their Appl. Tokyo, 2004. 178-18212. Berra P, Mathot S, Szeless B et al. Study, Construction and Test of a 3 GHz Linac-Booster (LIBO) for Cancer Therapy.Proc. of EPAC 2000. Vienna, 2000. 2495-249713. Peggs S, Cardona J, Brennan M et al. RCMS-A Second Generation Medical Synchrotron. Proc. of PAC 2001.Chicago, 2001. 2482-248414. Mori Y. Developments of FFAG Accelerators. Proc. of 17thInt. Conf. on Cyclotrons and Their Appl. Tokyo, 2004. 217-22115. Trbojevic D, Courant E D, Blaskiewicz M. Phys. Rev. Spec.Topics-Acc. And Beams, 2005, 8: 05010116. FU S N, FANG S X, GUAN X L et al. Construction of aHigh Current RFQ for ADS Study. Proc. of LINAC 2006.Knoxville, 2006. 165-16717. PENG Jun, FU Shi-Nian. High Power Laser and Particle Beams, 2008, 20(4): 579-584 (in Chinese)18. Furukawa T, Noda K, Muramatsu M et al. Nucl. Instrum.Methods A, 2004, 522: 196-20419. Hardt W. Ultraslow Extraction out LEAR, PS/DL/LEARNote 81-6. 199820. TANG J Y, LIU L, YANG Z et al. Phys. Rev. Spec. Topics-Acc. and Beams, 2009, 12: 05010121. Furukawa T, Noda K. Nucl. Instrum. Methods A, 2006,565: 430-43822. Jongen Y, Abs M, Bailey J et al. Progress Report on the Construction of the Proton Therapy Equipment for MGH.Proc. of EPAC98. Stockholm, 1998. 2354-235623. Pedroni E, Bearpark R, Boehringer T et al. Z. Med. Phys.,2004, 14: 25-34
  • 加载中

Get Citation
FANG Shou-Xian, GUAN Xia-Ling, TANG Jing-Yu, CHEN Yuan, DENG Chang-Dong, DONG Hai-Yi, FU Shi-Nian, JIAO Yi, SHU Hang, OUYANG Hua-Fu, QIU Jing, SHI Cai-Tu, SUN Hong, WEI Jie, YANG Mei and ZHANG Jing. ATPF—a dedicated proton therapy facility[J]. Chinese Physics C, 2010, 34(3): 383-388. doi: 10.1088/1674-1137/34/3/015
FANG Shou-Xian, GUAN Xia-Ling, TANG Jing-Yu, CHEN Yuan, DENG Chang-Dong, DONG Hai-Yi, FU Shi-Nian, JIAO Yi, SHU Hang, OUYANG Hua-Fu, QIU Jing, SHI Cai-Tu, SUN Hong, WEI Jie, YANG Mei and ZHANG Jing. ATPF—a dedicated proton therapy facility[J]. Chinese Physics C, 2010, 34(3): 383-388.  doi: 10.1088/1674-1137/34/3/015 shu
Milestone
Received: 2009-04-13
Revised: 2009-05-06
Article Metric

Article Views(2805)
PDF Downloads(704)
Cited by(0)
Policy on re-use
To reuse of subscription content published by CPC, the users need to request permission from CPC, unless the content was published under an Open Access license which automatically permits that type of reuse.
通讯作者: 陈斌, bchen63@163.com
  • 1. 

    沈阳化工大学材料科学与工程学院 沈阳 110142

  1. 本站搜索
  2. 百度学术搜索
  3. 万方数据库搜索
  4. CNKI搜索

Email This Article

Title:
Email:

ATPF—a dedicated proton therapy facility

    Corresponding author: TANG Jing-Yu,

Abstract: 

A proton therapy facility based on a linac injector and a slow-cycling synchrotron is proposed. To obtain good treatments for different cancer types, both the spot scanning method and the double-scattering method are adopted in the facility, whereas the nozzles include both gantry and fixed beam types. The proton accelerator chain includes a synchrotron of 250 MeV in maximum energy, an injector of 7 MeV consisting of an RFQ and a DTL linac, with a repetition rate of 0.5 Hz. The slow extraction using the third-order resonance and together with the RFKO method is considered to be a good method to obtain a stable and more-or-less homogenous beam spill. To benefit the spot scanning method, the extraction energy can be as many as about 200 between 60 MeV and 230 MeV. A new method—the emittance balancing technique of using a solenoid or a quadrupole rotator is proposed to solve the problem of unequal emittance in the two transverse planes with a beam slowly extracted from a synchrotron. The facility has been designed to keep the potential to be upgraded to include the carbon therapy in the future.

    HTML

Reference (1)

目录

/

DownLoad:  Full-Size Img  PowerPoint
Return
Return