×
近期发现有不法分子冒充我刊与作者联系,借此进行欺诈等不法行为,请广大作者加以鉴别,如遇诈骗行为,请第一时间与我刊编辑部联系确认(《中国物理C》(英文)编辑部电话:010-88235947,010-88236950),并作报警处理。
本刊再次郑重声明:
(1)本刊官方网址为cpc.ihep.ac.cn和https://iopscience.iop.org/journal/1674-1137
(2)本刊采编系统作者中心是投稿的唯一路径,该系统为ScholarOne远程稿件采编系统,仅在本刊投稿网网址(https://mc03.manuscriptcentral.com/cpc)设有登录入口。本刊不接受其他方式的投稿,如打印稿投稿、E-mail信箱投稿等,若以此种方式接收投稿均为假冒。
(3)所有投稿均需经过严格的同行评议、编辑加工后方可发表,本刊不存在所谓的“编辑部内部征稿”。如果有人以“编辑部内部人员”名义帮助作者发稿,并收取发表费用,均为假冒。
                  
《中国物理C》(英文)编辑部
2024年10月30日

Modeling process of the neutral beam re-ionization loss

Get Citation
LIANG Li-Zhen, HU Chun-Dong, XIE Yuan-Lai, XIE Ya-Hong and NBI-Team. Modeling process of the neutral beam re-ionization loss[J]. Chinese Physics C, 2010, 34(7): 972-977. doi: 10.1088/1674-1137/34/7/008
LIANG Li-Zhen, HU Chun-Dong, XIE Yuan-Lai, XIE Ya-Hong and NBI-Team. Modeling process of the neutral beam re-ionization loss[J]. Chinese Physics C, 2010, 34(7): 972-977.  doi: 10.1088/1674-1137/34/7/008 shu
Milestone
Received: 2009-07-27
Revised: 2009-12-27
Article Metric

Article Views(2638)
PDF Downloads(484)
Cited by(0)
Policy on re-use
To reuse of subscription content published by CPC, the users need to request permission from CPC, unless the content was published under an Open Access license which automatically permits that type of reuse.
通讯作者: 陈斌, bchen63@163.com
  • 1. 

    沈阳化工大学材料科学与工程学院 沈阳 110142

  1. 本站搜索
  2. 百度学术搜索
  3. 万方数据库搜索
  4. CNKI搜索

Email This Article

Title:
Email:

Modeling process of the neutral beam re-ionization loss

    Corresponding author: LIANG Li-Zhen,

Abstract: 

The basic process of re-ionization loss was studied. In the drift duct there are three processes leading to re-ionization loss: the collision of neutral beam particles with the molecules of background gas, similar collisions with released molecules from the inner wall of the drift duct and the ferret-collisions among particles with different energy of the neutral beam. Mathematical models have been developed and taking EAST-NBI parameters as an
example, the re-ionization loss was obtained within these models. The result indicated that in the early stage of the neutral beam injector operation the released gas was quite abundant. The amount of re-ionization loss owing to the released gas can be as high as 60%. In the case of a long-time operation of the neutral beam injector, the total re-ionization loss decreases from 13.7% to 5.7%. Then the re-ionization loss originating mainly from the collisions between particles of the neutral beam and the background molecules is dominant, covering about 92% of the total re-ionization loss. The drift duct pressure was the decisive factor for neutral beam re-ionization loss.

    HTML

Reference (1)

目录

/

DownLoad:  Full-Size Img  PowerPoint
Return
Return