×
近期发现有不法分子冒充我刊与作者联系,借此进行欺诈等不法行为,请广大作者加以鉴别,如遇诈骗行为,请第一时间与我刊编辑部联系确认(《中国物理C》(英文)编辑部电话:010-88235947,010-88236950),并作报警处理。
本刊再次郑重声明:
(1)本刊官方网址为cpc.ihep.ac.cn和https://iopscience.iop.org/journal/1674-1137
(2)本刊采编系统作者中心是投稿的唯一路径,该系统为ScholarOne远程稿件采编系统,仅在本刊投稿网网址(https://mc03.manuscriptcentral.com/cpc)设有登录入口。本刊不接受其他方式的投稿,如打印稿投稿、E-mail信箱投稿等,若以此种方式接收投稿均为假冒。
(3)所有投稿均需经过严格的同行评议、编辑加工后方可发表,本刊不存在所谓的“编辑部内部征稿”。如果有人以“编辑部内部人员”名义帮助作者发稿,并收取发表费用,均为假冒。
                  
《中国物理C》(英文)编辑部
2024年10月30日

Attenuation correction for dedicated breast PET using only emission data based on consistency conditions

Get Citation
WANG Lu, CHAI Pei, WU Li-Wei, YUN Ming-Kai, ZHOU Xiao-Lin, LIU Shuang-Quan, ZHANG Yu-Bao, SHAN Bao-Ci and WEI Long. Attenuation correction for dedicated breast PET using only emission data based on consistency conditions[J]. Chinese Physics C, 2013, 37(1): 018201. doi: 10.1088/1674-1137/37/1/018201
WANG Lu, CHAI Pei, WU Li-Wei, YUN Ming-Kai, ZHOU Xiao-Lin, LIU Shuang-Quan, ZHANG Yu-Bao, SHAN Bao-Ci and WEI Long. Attenuation correction for dedicated breast PET using only emission data based on consistency conditions[J]. Chinese Physics C, 2013, 37(1): 018201.  doi: 10.1088/1674-1137/37/1/018201 shu
Milestone
Received: 2012-02-28
Revised: 2012-05-15
Article Metric

Article Views(1988)
PDF Downloads(330)
Cited by(0)
Policy on re-use
To reuse of subscription content published by CPC, the users need to request permission from CPC, unless the content was published under an Open Access license which automatically permits that type of reuse.
通讯作者: 陈斌, bchen63@163.com
  • 1. 

    沈阳化工大学材料科学与工程学院 沈阳 110142

  1. 本站搜索
  2. 百度学术搜索
  3. 万方数据库搜索
  4. CNKI搜索

Email This Article

Title:
Email:

Attenuation correction for dedicated breast PET using only emission data based on consistency conditions

    Corresponding author: SHAN Bao-Ci,

Abstract: Accurate attenuation correction is required in dedicated breast PET imaging systems for image artifact removal and quantitative studies. In this study, a method using only emission data based on consistency conditions is proposed for attenuation correction in breast PET imaging systems. The consistency conditions are exploited to evaluate the accuracy of the estimated attenuation distribution and find the appropriate parameters that yield the most consistent attenuation distribution with the measured emission data. We have proved the validity of the method with the experimental investigations and the single-patient studies using a dedicated breast PET. The results show that the method is capable of accurately estimating the attenuation distribution of a uniform attenuator from the experimental data with various relatively low activities. The results also show that in single-patient studies, the method is robust for the irregular boundary of the breast tissue and provides a distinct improvement in image quality.

    HTML

目录

/

DownLoad:  Full-Size Img  PowerPoint
Return
Return