Attenuation length measurements of a liquid scintillator with LabVIEW and reliability evaluation of the device

Get Citation
GAO Long, YU Bo-Xiang, DING Ya-Yun, ZHOU Li, WEN Liang-Jian, XIE Yu-Guang, WANG Zhi-Gang, CAI Xiao, SUN Xi-Lei, FANG Jian, XUE Zhen, ZHANG Ai-Wu, SUN Li-Jun, GE Yong-Shuai, LIU Ying-Biao, NIU Shun-Li, HU Tao, CAO Jun, Attenuation length measurements of a liquid scintillator with LabVIEW and reliability evaluation of the device[J]. Chinese Physics C, 2013, 37(7): 076001. doi: 10.1088/1674-1137/37/7/076001
GAO Long, YU Bo-Xiang, DING Ya-Yun, ZHOU Li, WEN Liang-Jian, XIE Yu-Guang, WANG Zhi-Gang, CAI Xiao, SUN Xi-Lei, FANG Jian, XUE Zhen, ZHANG Ai-Wu, SUN Li-Jun, GE Yong-Shuai, LIU Ying-Biao, NIU Shun-Li, HU Tao, CAO Jun, Attenuation length measurements of a liquid scintillator with LabVIEW and reliability evaluation of the device[J]. Chinese Physics C, 2013, 37(7): 076001.  doi: 10.1088/1674-1137/37/7/076001 shu
Milestone
Received: 2012-09-26
Revised: 2012-10-15
Article Metric

Article Views(2154)
PDF Downloads(456)
Cited by(0)
Policy on re-use
To reuse of subscription content published by CPC, the users need to request permission from CPC, unless the content was published under an Open Access license which automatically permits that type of reuse.
通讯作者: 陈斌, bchen63@163.com
  • 1. 

    沈阳化工大学材料科学与工程学院 沈阳 110142

  1. 本站搜索
  2. 百度学术搜索
  3. 万方数据库搜索
  4. CNKI搜索

Email This Article

Title:
Email:

Attenuation length measurements of a liquid scintillator with LabVIEW and reliability evaluation of the device

    Corresponding author: GAO Long,
    Corresponding author: YU Bo-Xiang,

Abstract: An attenuation length measurement device was constructed using an oscilloscope and LabVIEW for signal acquisition and processing. The performance of the device has been tested in a variety of ways. The test results show that the set-up has a good stability and high precision (sigma/mean reached 0.4 percent). Besides, the accuracy of the measurement system will decrease by about 17 percent if a filter is used. The attenuation length of a gadolinium-loaded liquid scintillator (Gd-LS) was measured as 15.10±0.35 m where Gd-LS was heavily used in the Daya Bay Neutrino Experiment. In addition, one method based on the Beer-Lambert law was proposed to investigate the reliability of the measurement device, the R-square reached 0.9995. Moreover, three purification methods for Linear Alkyl Benzene (LAB) production were compared in the experiment.

    HTML

Reference (1)

目录

/

DownLoad:  Full-Size Img  PowerPoint
Return
Return