Experimental measurement of radiation dose in a dedicated breast CT system

Get Citation
SHEN Shan-Wei, WANG Yan-Fang, SHU Hang, TANG Xiao, WEI Cun-Feng, SONG Yu-Shou, SHI Rong-Jian and WEI Long. Experimental measurement of radiation dose in a dedicated breast CT system[J]. Chinese Physics C, 2014, 38(3): 038201. doi: 10.1088/1674-1137/38/3/038201
SHEN Shan-Wei, WANG Yan-Fang, SHU Hang, TANG Xiao, WEI Cun-Feng, SONG Yu-Shou, SHI Rong-Jian and WEI Long. Experimental measurement of radiation dose in a dedicated breast CT system[J]. Chinese Physics C, 2014, 38(3): 038201.  doi: 10.1088/1674-1137/38/3/038201 shu
Milestone
Received: 2013-04-22
Revised: 1900-01-01
Article Metric

Article Views(1949)
PDF Downloads(222)
Cited by(0)
Policy on re-use
To reuse of subscription content published by CPC, the users need to request permission from CPC, unless the content was published under an Open Access license which automatically permits that type of reuse.
通讯作者: 陈斌, bchen63@163.com
  • 1. 

    沈阳化工大学材料科学与工程学院 沈阳 110142

  1. 本站搜索
  2. 百度学术搜索
  3. 万方数据库搜索
  4. CNKI搜索

Email This Article

Title:
Email:

Experimental measurement of radiation dose in a dedicated breast CT system

    Corresponding author: SHEN Shan-Wei,

Abstract: Radiation dose is an important performance indicator of a dedicated breast CT (DBCT). In this paper, the method of putting thermoluminescent dosimeters (TLD) into a breast shaped PMMA phantom to study the dose distribution in breasts was improved by using smaller TLDs and a new half-ellipsoid PMMA phantom. Then the weighted CT dose index (CTDIw) was introduced to average glandular assessment in DBCT for the first time and two measurement modes were proposed for different sizes of breasts. The dose deviations caused by using cylindrical phantoms were simulated using the Monte Carlo method and a set of correction factors were calculated. The results of the confirmatory measurement with a cylindrical phantom (11 cm/8 cm) show that CTDIw gives a relatively conservative overestimate of the average glandular dose comparing to the results of Monte Carlo simulation and TLDs measurement. But with better practicability and stability, the CTDIw is suitable for dose evaluations in daily clinical practice. Both of the TLDs and CTDIw measurements demonstrate that the radiation dose of our DBCT system is lower than conventional two-view mammography.