Simulation of 200-400 MeV/u 12C+12C elastic scattering on SHARAQ spectrometer

  • In order to further obtain the information of three-body force (TBF) from 200-400 MeV/u 12C+12C elastic scattering, we plan to perform this experiment on a SHARAQ spectrometer. Based on the experimental condition of the Radioactive Ion Beam Factory (RIBF)-SHARAQ facility, a simulation is given to find a compromise between the better energy and angular resolutions, and higher yield by optimizing the target thickness, beam transport mode, beam intensity and angular step. From the simulation, we found that the beam quality mainly limits the improvements of energy and angular resolutions. A beam tracking system as well as a lateral and angular dispersion-matching technique are adopted to reduce the influence of beam quality. According to the two angular settings of SHARAQ as well as the expected cross sections on the basis of the theoretical model, the energy and angular resolutions, and statistical accuracy are estimated.
      PCAS:
  • 加载中
  • [1] Van Sen N, Yanlin Y, Arvieux J, Gaillard G. Nucl. Phys. A, 1987, 464(4): 717[2] Furumoto T, Sakuragi Y, Yamamoto Y. Phys. Rev. C, 2010, 82: 044612[3] Furumoto T, Sakuragi Y. Phys. Rev. C, 2013, 87: 014618[4] Uesaka T, Shimoura S, Sakai H, Berg G P A, Nakanishi K, Sasamoto Y, Saito A, Michimasa S, Kawabata T, Kubo T. Nucl. Instrum. Methods Phys. Res. B, 2008, 266: 4218[5] GUO C L, ZHANG G L, Tanihata I, LE X Y. Chin. Phys. C, 2012, 36(3): 205[6] Yoshiko S Study of the isovector non-spin-flip monopole resonance via the super-allowed Fermi type charge exchange (10C, 10Bβ) reaction PhD Thesis University of Tokyo, Japan; ed O. Hideaki et al Nuclear Structure Problems-Proceedings of the French-Japanese Symposium (Singapore: World Scientific) ISBN# 9789814417952 2013 148-151[7] Highland V L. Nucl. Instrum. Methods, 1975, 129: 497; Nucl. Instrum. Methods, 1979, 161: 171[8] Lynch G R, Dahl O I. Nucl. Instrum. Methods B, 1991, 58: 6[9] Kenjiro M. Study of the isovector spin monopole resonance via the (t, 3He) reactions at 300 MeV/u (PhD Thesis). University of Tokyo, Japan; Progress of Theoretical Physics Supplement, 2012, 196: 150
  • 加载中

Get Citation
YU Lei, ZHANG Gao-Long and LE Xiao-Yun. Simulation of 200-400 MeV/u 12C+12C elastic scattering on SHARAQ spectrometer[J]. Chinese Physics C, 2015, 39(2): 026201. doi: 10.1088/1674-1137/39/2/026201
YU Lei, ZHANG Gao-Long and LE Xiao-Yun. Simulation of 200-400 MeV/u 12C+12C elastic scattering on SHARAQ spectrometer[J]. Chinese Physics C, 2015, 39(2): 026201.  doi: 10.1088/1674-1137/39/2/026201 shu
Milestone
Received: 2014-04-01
Revised: 1900-01-01
Article Metric

Article Views(1827)
PDF Downloads(180)
Cited by(0)
Policy on re-use
To reuse of subscription content published by CPC, the users need to request permission from CPC, unless the content was published under an Open Access license which automatically permits that type of reuse.
通讯作者: 陈斌, bchen63@163.com
  • 1. 

    沈阳化工大学材料科学与工程学院 沈阳 110142

  1. 本站搜索
  2. 百度学术搜索
  3. 万方数据库搜索
  4. CNKI搜索

Email This Article

Title:
Email:

Simulation of 200-400 MeV/u 12C+12C elastic scattering on SHARAQ spectrometer

    Corresponding author: ZHANG Gao-Long,

Abstract: In order to further obtain the information of three-body force (TBF) from 200-400 MeV/u 12C+12C elastic scattering, we plan to perform this experiment on a SHARAQ spectrometer. Based on the experimental condition of the Radioactive Ion Beam Factory (RIBF)-SHARAQ facility, a simulation is given to find a compromise between the better energy and angular resolutions, and higher yield by optimizing the target thickness, beam transport mode, beam intensity and angular step. From the simulation, we found that the beam quality mainly limits the improvements of energy and angular resolutions. A beam tracking system as well as a lateral and angular dispersion-matching technique are adopted to reduce the influence of beam quality. According to the two angular settings of SHARAQ as well as the expected cross sections on the basis of the theoretical model, the energy and angular resolutions, and statistical accuracy are estimated.

    HTML

Reference (1)

目录

/

DownLoad:  Full-Size Img  PowerPoint
Return
Return