×
近期发现有不法分子冒充我刊与作者联系,借此进行欺诈等不法行为,请广大作者加以鉴别,如遇诈骗行为,请第一时间与我刊编辑部联系确认(《中国物理C》(英文)编辑部电话:010-88235947,010-88236950),并作报警处理。
本刊再次郑重声明:
(1)本刊官方网址为cpc.ihep.ac.cn和https://iopscience.iop.org/journal/1674-1137
(2)本刊采编系统作者中心是投稿的唯一路径,该系统为ScholarOne远程稿件采编系统,仅在本刊投稿网网址(https://mc03.manuscriptcentral.com/cpc)设有登录入口。本刊不接受其他方式的投稿,如打印稿投稿、E-mail信箱投稿等,若以此种方式接收投稿均为假冒。
(3)所有投稿均需经过严格的同行评议、编辑加工后方可发表,本刊不存在所谓的“编辑部内部征稿”。如果有人以“编辑部内部人员”名义帮助作者发稿,并收取发表费用,均为假冒。
                  
《中国物理C》(英文)编辑部
2024年10月30日

Study of neutron dose equivalent at the HIRFL deep tumor therapy terminal

Get Citation
Jun-Kui Xu, You-Wu Su, Wu-Yuan Li, Wei-Wei Yan, Zong-Qiang Li, Wang Mao, Cheng-Guo Pang and Chong Xu. Study of neutron dose equivalent at the HIRFL deep tumor therapy terminal[J]. Chinese Physics C, 2017, 41(6): 068201. doi: 10.1088/1674-1137/41/6/068201
Jun-Kui Xu, You-Wu Su, Wu-Yuan Li, Wei-Wei Yan, Zong-Qiang Li, Wang Mao, Cheng-Guo Pang and Chong Xu. Study of neutron dose equivalent at the HIRFL deep tumor therapy terminal[J]. Chinese Physics C, 2017, 41(6): 068201.  doi: 10.1088/1674-1137/41/6/068201 shu
Milestone
Received: 2016-07-12
Revised: 2016-12-04
Article Metric

Article Views(1561)
PDF Downloads(44)
Cited by(0)
Policy on re-use
To reuse of subscription content published by CPC, the users need to request permission from CPC, unless the content was published under an Open Access license which automatically permits that type of reuse.
通讯作者: 陈斌, bchen63@163.com
  • 1. 

    沈阳化工大学材料科学与工程学院 沈阳 110142

  1. 本站搜索
  2. 百度学术搜索
  3. 万方数据库搜索
  4. CNKI搜索

Email This Article

Title:
Email:

Study of neutron dose equivalent at the HIRFL deep tumor therapy terminal

    Corresponding author: Jun-Kui Xu,
    Corresponding author: You-Wu Su,
  • 1. Institute of Modern Physics, Chinese Academy of Sciences, Lanzhou 730000, China
  • 2. School of Nuclear Science and Technology, Lanzhou University, Lanzhou 730000, China
  • 3.  Institute of Modern Physics, Chinese Academy of Sciences, Lanzhou 730000, China
  • 4.  School of Nuclear Science and Technology, Lanzhou University, Lanzhou 730000, China

Abstract: The secondary neutron fields at the deep tumor therapy terminal at HIRFL (Heavy Ion Research Facility in Lanzhou) were investigated. The distributions of neutron ambient dose equivalent were measured with a FHT762 Wendi-II neutron ambient dose equivalent meter as 12C ions with energies of 165, 207, 270, and 350 MeV/u were bombarded on thick tissue-like targets. The thickness of targets used in the experiments was larger than the range of the carbon ions. The neutron spectra and dose equivalent were simulated by using FLUKA code, and the results agree well with the experimental data. The experiment results showed that the neutron dose produced by fragmentation reactions in tissue can be neglected in carbon-ion therapy, even considering their enhanced biological effectiveness. These results are also valuable for radiation protection, especially in the shielding design of high energy heavy ion medical machines.

    HTML

Reference (18)

目录

/

DownLoad:  Full-Size Img  PowerPoint
Return
Return