×
近期发现有不法分子冒充我刊与作者联系,借此进行欺诈等不法行为,请广大作者加以鉴别,如遇诈骗行为,请第一时间与我刊编辑部联系确认(《中国物理C》(英文)编辑部电话:010-88235947,010-88236950),并作报警处理。
本刊再次郑重声明:
(1)本刊官方网址为cpc.ihep.ac.cn和https://iopscience.iop.org/journal/1674-1137
(2)本刊采编系统作者中心是投稿的唯一路径,该系统为ScholarOne远程稿件采编系统,仅在本刊投稿网网址(https://mc03.manuscriptcentral.com/cpc)设有登录入口。本刊不接受其他方式的投稿,如打印稿投稿、E-mail信箱投稿等,若以此种方式接收投稿均为假冒。
(3)所有投稿均需经过严格的同行评议、编辑加工后方可发表,本刊不存在所谓的“编辑部内部征稿”。如果有人以“编辑部内部人员”名义帮助作者发稿,并收取发表费用,均为假冒。
                  
《中国物理C》(英文)编辑部
2024年10月30日

Beam distribution reconstruction simulation for electron beam probe

  • An electron beam probe (EBP) is a detector which makes use of a low-intensity and low-energy electron beam to measure the transverse profile, bunch shape, beam neutralization and beam wake field of an intense beam with small dimensions. While it can be applied to many aspects, we limit our analysis to beam distribution reconstruction. This kind of detector is almost non-interceptive for all of the beam and does not disturb the machine environment. In this paper, we present the theoretical aspects behind this technique for beam distribution measurement and some simulation results of the detector involved. First, a method to obtain a parallel electron beam is introduced and a simulation code is developed. An EBP as a profile monitor for dense beams is then simulated using the fast scan method for various target beam profiles, including KV distribution, waterbag distribution, parabolic distribution, Gaussian distribution and halo distribution. Profile reconstruction from the deflected electron beam trajectory is implemented and compared with the actual profile, and the expected agreement is achieved. Furthermore, as well as fast scan, a slow scan, i.e. step-by-step scan, is considered, which lowers the requirement for hardware, i.e. Radio Frequency deflector. We calculate the three-dimensional electric field of a Gaussian distribution and simulate the electron motion in this field. In addition, a fast scan along the target beam direction and slow scan across the beam are also presented, and can provide a measurement of longitudinal distribution as well as transverse profile simultaneously. As an example, simulation results for the China Accelerator Driven Sub-critical System (CADS) and High Intensity Heavy Ion Accelerator Facility (HIAF) are given. Finally, a potential system design for an EBP is described.
      PCAS:
  • 加载中
  • [1] B. Hochadel, F. Albrecht, M. Grieser et al, Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 343(2): 401-414 (1994)
    [2] F. Becker, C. Andre, P. Forck et al, Beam Induced Fluorescence (BIF) Monitor for Transverse Profile Determination of 5 TO 750 MeV/u Heavy Ion Beams, in Proceedings of the 10th European Workshop on Beam Diagnostics and Instrumentation for Particle Accelerators (DIPAC), p.33
    [3] P. D. Goldan, Physics of Fluids, 13(4): 1055-1059 (1970)
    [4] C. H. Stallings, Journal of Applied Physics, 42(7): 2831-2834 (1971)
    [5] P. K. Roy, S. S. Yu, E. Henestroza et al, Review of Scientific Instruments, 76(2): 1 (2005)
    [6] W. Blokland, S. Aleksandrov, S. Cousinea et al, Electron Scanner for SNS Ring Profile Measurements, in Proceedings of the 9th European Workshop on Beam Diagnostics and Instrumentation for Particle Accelerators (DIPAC), p.155
    [7] W. Blokland, Non-invasive Beam Profile Measurements using an Electron-Beam Scanner, in Proceedings of the 46th ICFA Advanced Beam Dynamics Workshop on High-Intensity and High-Brightness Hadron Beams (HB), p.438
    [8] W. Blokland, S. Cousineau, A Non-Destructive Profile Monitor for High Intensity Beams, in Proceedings of 2011 Particle Accelerator Conference (PAC), p.1438
    [9] R. M. Thurman-Keup, M. L. Alvarez, J. Fitzgerald et al, Electron Beam Profiler for the Fermilab Main Injector, in Proceedings of the 3rd International Beam Instrumentation Conference (IBIC), p.398
    [10] R. M. Thurman-Keup, M. L. Alvarez, J. Fitzgerald et al, Installation Status of the Electron Beam Profiler for the Fermilab Main Injector, in Proceedings of the 4rd International Beam Instrumentation Conference (IBIC), p.535
    [11] P. V. Logatchov, P. A. Bak, A. A. Starostenko et al, Non-Destructive Singlepass Monitor of Longitudinal Charge Distribution in An Ultrarelativistic Electron Bunch, in Proceedings of the 1999 Particle Accelerator Conference (PAC), p.2167
    [12] A. A. Starostenko, P. A. Bak, Y. A. Gusev et al, Nnon-Destructive Singlepass Bunch Length Monitor: Experiments at VEPP-5 Preinjector Electron Linac, in Proceedings of the seventh European Particle Accelerator Conference (EPAC), p.1720
    [13] P. V. Logachev, D. A. Malyutin, A. A. Starostenko, Instruments and Experimental Techniques, 51(1): 1-27 (2008)
    [14] P. V. Logachev, O. I. Meshkov, A. A. Starostenko, Physics of Particles and Nuclei, 47(2): 236-269 (2016)
    [15] J. Bosser, C. Dimopoulou, A. Feschenko, Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 484(1): 1-16 (2002)
    [16] J. A. Pasour, M. T. Ngo, Review of Scientific Instruments, 68(3): 1409-1417 (1997)
    [17] J. C. Yang, J. W. Xia, G. Q. Xiao, Nuclear Instruments and Methods in Physics Research Section B: Beam Interactions with Materials and Atoms, 317(1): 263-265 (2013)
    [18] Z. H. Li, P. Cheng, and H. P. Geng, Phys. Rev. ST Accel. Beams, 16(8): 080101 (2013)
    [19] A. Aleksandrov, S. Assadi, S. Cousineau et al, Feasibility Study of Using an Electron Beam For Profile Measurements in the SNS Accumulator Ring, in Proceedings of 2005 Particle Accelerator Conference (PAC), p.2586
    [20] P. V. Logachev, D. A. Malyutin, A. A. Starostenko, Instruments and Experimental Techniques, 52(4): 569-573 (2009)
    [21] I. Kapchinskij, V. Vladimirskij, Limitations of Proton Beam Current in a Strong Focusing Linear Accelerator Associated with the Beam Space Charge, in Proceedings of the International Conference on High Energy Accelerators (HEACC), p.274
    [22] https://lib-extopc.kek.jp/preprints/PDF/1982/8203/8203088.pdf, retrieved 10th December 2016
    [23] K. Takayama, Lettere al Nuovo Cimento (1971-1985), 34(7): 190-192 (1982)
    [24] K. Takayama, IEEE Transactions on Nuclear Science, 30(4): 2661-2662 (1983)
    [25] https://cds.cern.ch/record/122227/files/198005132.pdf, retrieved 10th December 2016
    [26] R. Wanzenberg, Nonlinear Motion of a Point Charge in the 3D Space Charge Field of a Gaussian Bunch, Internal Report, DESY M 10-01
  • 加载中

Get Citation
Yong-Chun Feng, Rui-Shi Mao, Peng Li, Xin-Cai Kang, Yan Yin, Tong Liu, Yao-Yao You, Yu-Cong Chen, Tie-Cheng Zhao, Zhi-Guo Xu, Yan-Yu Wang and You-Jin Yuan. Beam distribution reconstruction simulation for electron beam probe[J]. Chinese Physics C, 2017, 41(7): 077001. doi: 10.1088/1674-1137/41/7/077001
Yong-Chun Feng, Rui-Shi Mao, Peng Li, Xin-Cai Kang, Yan Yin, Tong Liu, Yao-Yao You, Yu-Cong Chen, Tie-Cheng Zhao, Zhi-Guo Xu, Yan-Yu Wang and You-Jin Yuan. Beam distribution reconstruction simulation for electron beam probe[J]. Chinese Physics C, 2017, 41(7): 077001.  doi: 10.1088/1674-1137/41/7/077001 shu
Milestone
Received: 2016-12-29
Article Metric

Article Views(1852)
PDF Downloads(68)
Cited by(0)
Policy on re-use
To reuse of subscription content published by CPC, the users need to request permission from CPC, unless the content was published under an Open Access license which automatically permits that type of reuse.
通讯作者: 陈斌, bchen63@163.com
  • 1. 

    沈阳化工大学材料科学与工程学院 沈阳 110142

  1. 本站搜索
  2. 百度学术搜索
  3. 万方数据库搜索
  4. CNKI搜索

Email This Article

Title:
Email:

Beam distribution reconstruction simulation for electron beam probe

    Corresponding author: Rui-Shi Mao,
  • 1. Institute of Modern Physics, Chinese Academy of Sciences, Lanzhou 730000, China
  • 2. University of Chinese Academy of Sciences, Beijing 100049, China
  • 3.  Institute of Modern Physics, Chinese Academy of Sciences, Lanzhou 730000, China

Abstract: An electron beam probe (EBP) is a detector which makes use of a low-intensity and low-energy electron beam to measure the transverse profile, bunch shape, beam neutralization and beam wake field of an intense beam with small dimensions. While it can be applied to many aspects, we limit our analysis to beam distribution reconstruction. This kind of detector is almost non-interceptive for all of the beam and does not disturb the machine environment. In this paper, we present the theoretical aspects behind this technique for beam distribution measurement and some simulation results of the detector involved. First, a method to obtain a parallel electron beam is introduced and a simulation code is developed. An EBP as a profile monitor for dense beams is then simulated using the fast scan method for various target beam profiles, including KV distribution, waterbag distribution, parabolic distribution, Gaussian distribution and halo distribution. Profile reconstruction from the deflected electron beam trajectory is implemented and compared with the actual profile, and the expected agreement is achieved. Furthermore, as well as fast scan, a slow scan, i.e. step-by-step scan, is considered, which lowers the requirement for hardware, i.e. Radio Frequency deflector. We calculate the three-dimensional electric field of a Gaussian distribution and simulate the electron motion in this field. In addition, a fast scan along the target beam direction and slow scan across the beam are also presented, and can provide a measurement of longitudinal distribution as well as transverse profile simultaneously. As an example, simulation results for the China Accelerator Driven Sub-critical System (CADS) and High Intensity Heavy Ion Accelerator Facility (HIAF) are given. Finally, a potential system design for an EBP is described.

    HTML

Reference (26)

目录

/

DownLoad:  Full-Size Img  PowerPoint
Return
Return