Time-Resolved Emittance Measurement of Intense Pulse Beams Using the Modified Three Gradient Method

Get Citation
YANG Guo-Jun, ZHANG Zhuo, CHEN Si-Fu, LIU Cheng-Jun and LIN Yu-Zheng. Time-Resolved Emittance Measurement of Intense Pulse Beams Using the Modified Three Gradient Method[J]. Chinese Physics C, 2005, 29(2): 191-196.
YANG Guo-Jun, ZHANG Zhuo, CHEN Si-Fu, LIU Cheng-Jun and LIN Yu-Zheng. Time-Resolved Emittance Measurement of Intense Pulse Beams Using the Modified Three Gradient Method[J]. Chinese Physics C, 2005, 29(2): 191-196. shu
Milestone
Received: 2004-06-16
Revised: 2004-07-26
Article Metric

Article Views(2830)
PDF Downloads(611)
Cited by(0)
Policy on re-use
To reuse of subscription content published by CPC, the users need to request permission from CPC, unless the content was published under an Open Access license which automatically permits that type of reuse.
通讯作者: 陈斌, bchen63@163.com
  • 1. 

    沈阳化工大学材料科学与工程学院 沈阳 110142

  1. 本站搜索
  2. 百度学术搜索
  3. 万方数据库搜索
  4. CNKI搜索

Email This Article

Title:
Email:

Time-Resolved Emittance Measurement of Intense Pulse Beams Using the Modified Three Gradient Method

    Corresponding author: YANG Guo-Jun,
  • Department of Engineering Physics,Tsinghua University,Beijing 100084,China2 Institute of Fluid Physics,CAEP,Mianyang 621900,China

Abstract: The three gradient method is a conventional means for beam emittance measurement. In intense electron beam accelerators,since the space charge effect is remarkable, the conventional three gradient method in not available.A MTGM(abbreviation for the Modified Three Gradient Method)is an improvement of the conventional three gradient method, the space charge effect is included in this method. In this paper, the basic theory of MTGM is stated, the principle of applying the MTGM method to beam diagnostics is described. Experiments are carried out on two electron beams of 3.5MeV, 2.6kA, 100ns and 18MeV,2.6kA 100ns separately, which scheme is presented. Results of these experiments are presented together with the error analysis. The results show that the MTGM method is an effective way of emittance measurement for intense pulse electron beam.

    HTML

Reference (1)

目录

/

DownLoad:  Full-Size Img  PowerPoint
Return
Return