Measurement and Adjustment of Dumb-Bells for 9-cell TESLA Cavity

Get Citation
XU Wen-Can, QUAN Sheng-Wen, HAO Jian-Kui, JIANG Tao, ZHANG Bao-Cheng and ZHAO Kui. Measurement and Adjustment of Dumb-Bells for 9-cell TESLA Cavity[J]. Chinese Physics C, 2008, 32(S1): 154-156.
XU Wen-Can, QUAN Sheng-Wen, HAO Jian-Kui, JIANG Tao, ZHANG Bao-Cheng and ZHAO Kui. Measurement and Adjustment of Dumb-Bells for 9-cell TESLA Cavity[J]. Chinese Physics C, 2008, 32(S1): 154-156. shu
Milestone
Received: 2008-01-10
Revised: 1900-01-01
Article Metric

Article Views(3505)
PDF Downloads(610)
Cited by(0)
Policy on re-use
To reuse of subscription content published by CPC, the users need to request permission from CPC, unless the content was published under an Open Access license which automatically permits that type of reuse.
通讯作者: 陈斌, bchen63@163.com
  • 1. 

    沈阳化工大学材料科学与工程学院 沈阳 110142

  1. 本站搜索
  2. 百度学术搜索
  3. 万方数据库搜索
  4. CNKI搜索

Email This Article

Title:
Email:

Measurement and Adjustment of Dumb-Bells for 9-cell TESLA Cavity

    Corresponding author: XU Wen-Can,

Abstract: Correct Dumb-bells are very important to make sure the right field flatness, frequency of TM010 mode and length of 9-cell TESLA cavity. The shape of the dumb-bells will be wrong due to deep drawing, machining and EB welding. Then, the dumb-bells should be adjusted after iris and stiffness welding according to the mechanical and microwave measurement. Peking University has set up facilities for measuring and correcting the dumb-bells. This paper discusses the method of measuring and correcting the dumb-bells.