SHAPE MEASUREMENT OF SYNCHROTRON RADIATION WITH HIGH TIME RESOLUTION

Get Citation
CAO Zhong, LIU Wei-Ren, WANG Li-Lie, XIE Shi-Liang, JIANG Li-Ping, DING Mei-Song, ZHAO Ji-Lai, REN You-Lai, SHAN Bing, ZHAO Zheng and CUI Ming-Qi. SHAPE MEASUREMENT OF SYNCHROTRON RADIATION WITH HIGH TIME RESOLUTION[J]. Chinese Physics C, 1990, 14(8): 677-683.
CAO Zhong, LIU Wei-Ren, WANG Li-Lie, XIE Shi-Liang, JIANG Li-Ping, DING Mei-Song, ZHAO Ji-Lai, REN You-Lai, SHAN Bing, ZHAO Zheng and CUI Ming-Qi. SHAPE MEASUREMENT OF SYNCHROTRON RADIATION WITH HIGH TIME RESOLUTION[J]. Chinese Physics C, 1990, 14(8): 677-683. shu
Milestone
Received: 1900-01-01
Revised: 1900-01-01
Article Metric

Article Views(2605)
PDF Downloads(462)
Cited by(0)
Policy on re-use
To reuse of subscription content published by CPC, the users need to request permission from CPC, unless the content was published under an Open Access license which automatically permits that type of reuse.
通讯作者: 陈斌, bchen63@163.com
  • 1. 

    沈阳化工大学材料科学与工程学院 沈阳 110142

  1. 本站搜索
  2. 百度学术搜索
  3. 万方数据库搜索
  4. CNKI搜索

Email This Article

Title:
Email:

SHAPE MEASUREMENT OF SYNCHROTRON RADIATION WITH HIGH TIME RESOLUTION

    Corresponding author: CAO Zhong,
  • China Institute of Atomic Energy,Beijing1 Xian Institute of Optics and Precision Mechanics2 Institute of High Energy Physics,Academia Sinica,Beijing

Abstract: By using BWS-5k II streak camera made in China,we have measured the time structure of Synchrotron Radiation (SR) from the relatrivistic electron and positron beam bunches of Beijing Electron Positron Collider (BEPC).The dependence of SR width to the intensity of beam current and the voltage of RF source was also measured.The main data taken with 30ps time resolution in the experiment are as follows: The length of VR at Ee=1.549GeV is changed from 220ps to 670ps when the average beam current from 2mA to 30mA,the variation range of CR length at 20mA beam current is 500—700ps with RF source voltage varying between 250kV and 500kV.The time calibration uncertainty of the experiment is ±15%.The trigger jitter is less than ±200ps.