×
近期发现有不法分子冒充我刊与作者联系,借此进行欺诈等不法行为,请广大作者加以鉴别,如遇诈骗行为,请第一时间与我刊编辑部联系确认(《中国物理C》(英文)编辑部电话:010-88235947,010-88236950),并作报警处理。
本刊再次郑重声明:
(1)本刊官方网址为cpc.ihep.ac.cn和https://iopscience.iop.org/journal/1674-1137
(2)本刊采编系统作者中心是投稿的唯一路径,该系统为ScholarOne远程稿件采编系统,仅在本刊投稿网网址(https://mc03.manuscriptcentral.com/cpc)设有登录入口。本刊不接受其他方式的投稿,如打印稿投稿、E-mail信箱投稿等,若以此种方式接收投稿均为假冒。
(3)所有投稿均需经过严格的同行评议、编辑加工后方可发表,本刊不存在所谓的“编辑部内部征稿”。如果有人以“编辑部内部人员”名义帮助作者发稿,并收取发表费用,均为假冒。
                  
《中国物理C》(英文)编辑部
2024年10月30日

Use of Monte Carlo Method to Evaluate the Response of Direct Conversion X-Ray Detectors

  • The response of three semiconductor materials, polycrystalline HgI2, amorphous Se and polycrystalline CdTe, used for large area direct conversion detectors, is simulated by Monte Carlo method for X-ray photons in the diagnostic energy range (10—100keV). The simulation involves the transmission spectra, backscatting spectra, absorption efficiency and charge sensitivity. The interaction process between X-ray photons and the conversion materials is simulated by EGSnrc Monte Carlo code system and for the generation of signal charges Gaussian noise and the collection of partial charges are taken into account. The results show that deep traps in materials can affect largely detecting sensitivity when the mean free length (Schubweg) of carriers is less than the materials thickness. The sensitivity of HgI2 is 5 times higher than that of amorphous Se and CdTe is 10 times higher than amorphous Se, it can be seen that a high Z material can improve the detecting sensitivity greatly.
  • 加载中
  • [1] . Haghigat A, Jeraj R, NewhauserWet al. Med. Phys., 2006,33: 21322. Strigari Lidia, Menghi Enrico, D'Andrea Marco et al. Med.Phys., 2006, 33: 33833. Kum. Med. Phys., 2006, 33: 21224. Ay M R, Sarkar S, Shahriari M et al. Med. Phys., 2005, 32:16605. Korn Alexander, Giersch Juergen, Hoheisel Martin. Proc.SPIE, 2005, 5745: 2926. Hoheisel Martin, Giersch Jurgen, Mitschke Michaela et al.Proc. SPIE, 2004, 5368: 3867. Guerra Del, Nelson W R, Russso P. Nuclear Instrumentsand Methods in Physics Research, 1991, A306: 3788. Conti M, Guerra A Del, Mazzei D et al. Nuclear Instru-ments and Methods in Physics Research, 1992, A322: 5919. Olmos P, Perez J M, Garcia-Belmonte G et al. Nuclear In-struments and Methods in Physics Research, 1991, A302:9110. Fano U. Phys. Rev., 1947, 72: 2611. Cavalleri G, Gatti E, Fabri G et al. Nucl. Instrum. Meth-ods, 1971, 92: 13712. Kasap S O. J. Phys. D: Appl. Phys., 2000, 33: 285313. Lederer C M, Shirley V S. Table of Isotopes. 7th Edition.New York: Wiley, 1978, 414. Storm E, Israel H I. Atom. Data Nucl. Data Tables, 1970,7: 56515. Winick Herman. X-ray Data Booklet. Lawrence BerkeleyNational Laboratory University of California, Berkeley, CA94720, 200116. Kabir M Z, Kasap S O, ZHAO W et al. IEE Proc.-CircuitsDevices Syst., 2003, 150: 25817. Yin Shi, Tumer Tumay O, Maeding Dale et al. IEEE Trans-actions on Nuclear Science, 2002, 49(1): 17618. Kolosov S A, Klevkov Yu V, Plotnikov A F. Semiconductors, 2004, 38(4): 455
  • 加载中

Get Citation
GUI Jian-Bao, GUO Jin-Chuan, YANG Qin-Lao and NIU Han-Ben. Use of Monte Carlo Method to Evaluate the Response of Direct Conversion X-Ray Detectors[J]. Chinese Physics C, 2007, 31(10): 933-937.
GUI Jian-Bao, GUO Jin-Chuan, YANG Qin-Lao and NIU Han-Ben. Use of Monte Carlo Method to Evaluate the Response of Direct Conversion X-Ray Detectors[J]. Chinese Physics C, 2007, 31(10): 933-937. shu
Milestone
Received: 2006-12-05
Revised: 2007-03-09
Article Metric

Article Views(2990)
PDF Downloads(697)
Cited by(0)
Policy on re-use
To reuse of subscription content published by CPC, the users need to request permission from CPC, unless the content was published under an Open Access license which automatically permits that type of reuse.
通讯作者: 陈斌, bchen63@163.com
  • 1. 

    沈阳化工大学材料科学与工程学院 沈阳 110142

  1. 本站搜索
  2. 百度学术搜索
  3. 万方数据库搜索
  4. CNKI搜索

Email This Article

Title:
Email:

Use of Monte Carlo Method to Evaluate the Response of Direct Conversion X-Ray Detectors

    Corresponding author: GUI Jian-Bao,
  • Institute of Optoelectronics Science and Engineering, Huazhong University of Science and Technology, Wuhan 430074, China2 Institute of Optoelectronics, Shenzhen University, Shenzhen 518060, China

Abstract: The response of three semiconductor materials, polycrystalline HgI2, amorphous Se and polycrystalline CdTe, used for large area direct conversion detectors, is simulated by Monte Carlo method for X-ray photons in the diagnostic energy range (10—100keV). The simulation involves the transmission spectra, backscatting spectra, absorption efficiency and charge sensitivity. The interaction process between X-ray photons and the conversion materials is simulated by EGSnrc Monte Carlo code system and for the generation of signal charges Gaussian noise and the collection of partial charges are taken into account. The results show that deep traps in materials can affect largely detecting sensitivity when the mean free length (Schubweg) of carriers is less than the materials thickness. The sensitivity of HgI2 is 5 times higher than that of amorphous Se and CdTe is 10 times higher than amorphous Se, it can be seen that a high Z material can improve the detecting sensitivity greatly.

    HTML

Reference (1)

目录

/

DownLoad:  Full-Size Img  PowerPoint
Return
Return