近期发现有不法分子冒充我刊与作者联系,借此进行欺诈等不法行为,请广大作者加以鉴别,如遇诈骗行为,请第一时间与我刊编辑部联系确认(《中国物理C》(英文)编辑部电话:010-88235947,010-88236950),并作报警处理。
本刊再次郑重声明:
(1)本刊官方网址为cpc.ihep.ac.cn和https://iopscience.iop.org/journal/1674-1137
(2)本刊采编系统作者中心是投稿的唯一路径,该系统为ScholarOne远程稿件采编系统,仅在本刊投稿网网址(https://mc03.manuscriptcentral.com/cpc)设有登录入口。本刊不接受其他方式的投稿,如打印稿投稿、E-mail信箱投稿等,若以此种方式接收投稿均为假冒。
(3)所有投稿均需经过严格的同行评议、编辑加工后方可发表,本刊不存在所谓的“编辑部内部征稿”。如果有人以“编辑部内部人员”名义帮助作者发稿,并收取发表费用,均为假冒。
                  
《中国物理C》(英文)编辑部
2024年10月30日

Influence of Angle Range of Recording A Hologram to the Reconstructed Atomic Image in X-ray Fluorescence Holography

  • X-ray fluorescence holography is a novel method for three-dimensional (3D) imaging of local atomic structure.Theoretically,in an XFH experiment,one has to measure the fluorescence energy on a spherical surface with angular resolution in the degree range to get well-resolved three-dimensional (3D) images of atoms.But in practice,experimental system arrangement of XFH does not allow the measurement of the fluorescent intensity oscillations in the full sphere.The holographic informaion loss because of the limited sampling range (less than 4π) will directly result in defective reconstructed atomic images.In this work,we investigate the influence of angle range and step of recording an X-ray fluorescence hologram on reconstructed atomic images by numerically simulating X-ray fluorescence holograms of Fe single crystal at different recording angle range and step.The Fe atomic images in the plane parallel to the crystal (001) crystallographic plane reconstructed from these simulated holograms can show this influence.The incomplete range of azimuth angle causes inhomogeneous brightness of the reconstructed atomic images.The incomplete range of polar angle causes the reconstructed atomic positions slightly shifted toward the central site and the increase of background brightness.The influence of the polar angle step on the reconstructed atomic images can be ignored if the step is enough small.
  • 加载中
  • [1] Gahor D. Nature, 1948, 161 :7772 Szoke A. In: Short Wavelength Coherent Radiation: Generation and Applications, edited by Atwood T and Boker J , AIP Conf. Proc.1986, 147 ( AIP, New York) :3613 Harp G R , Saldin D K , Tanner B P. Phys. Rev. Lett. , 1990, 65:10124 Tegze M , Faigel G. Nature, 1996, 380 :495 Adams B, Novikov D V et al. Phys. Rev. , 1998, B57:75266 Tegze M, Faigel G et al. Phys. Rev. Lett. , 1999, 82:48477 Marchesini S et al. Phys. Rev. Lett. , 2000, 85 :47238 John S. Nature, 2001 , 410 : 10379 Kopecky M et al. Phys. Rev. Lett. , 2002, 88 : 18550310 Faigel G, Tegze M. Rep. Prog. Phys. , 1999, 62 :35511 Born M , Wolf E. Principles of Optics, 1959, (London: Pergamon)12 Barton J J. Phys. Rev. Lett. , 1988, 61 :I356
  • 加载中

Get Citation
XIE Hong-Lan, CHEN Jian-Wen, GAO Hong-Yi, LI Ru-Xin and XU Zhi-Zhan. Influence of Angle Range of Recording A Hologram to the Reconstructed Atomic Image in X-ray Fluorescence Holography[J]. Chinese Physics C, 2003, 27(S1): 86-91.
XIE Hong-Lan, CHEN Jian-Wen, GAO Hong-Yi, LI Ru-Xin and XU Zhi-Zhan. Influence of Angle Range of Recording A Hologram to the Reconstructed Atomic Image in X-ray Fluorescence Holography[J]. Chinese Physics C, 2003, 27(S1): 86-91. shu
Milestone
Received: 2003-11-21
Revised: 1900-01-01
Article Metric

Article Views(1645)
PDF Downloads(571)
Cited by(0)
Policy on re-use
To reuse of subscription content published by CPC, the users need to request permission from CPC, unless the content was published under an Open Access license which automatically permits that type of reuse.
通讯作者: 陈斌, bchen63@163.com
  • 1. 

    沈阳化工大学材料科学与工程学院 沈阳 110142

  1. 本站搜索
  2. 百度学术搜索
  3. 万方数据库搜索
  4. CNKI搜索

Email This Article

Title:
Email:

Influence of Angle Range of Recording A Hologram to the Reconstructed Atomic Image in X-ray Fluorescence Holography

    Corresponding author: CHEN Jian-Wen,
  • Shanghai Institute of Optics and Fine Mechanics,CAS,Shanghai 201800,China

Abstract: X-ray fluorescence holography is a novel method for three-dimensional (3D) imaging of local atomic structure.Theoretically,in an XFH experiment,one has to measure the fluorescence energy on a spherical surface with angular resolution in the degree range to get well-resolved three-dimensional (3D) images of atoms.But in practice,experimental system arrangement of XFH does not allow the measurement of the fluorescent intensity oscillations in the full sphere.The holographic informaion loss because of the limited sampling range (less than 4π) will directly result in defective reconstructed atomic images.In this work,we investigate the influence of angle range and step of recording an X-ray fluorescence hologram on reconstructed atomic images by numerically simulating X-ray fluorescence holograms of Fe single crystal at different recording angle range and step.The Fe atomic images in the plane parallel to the crystal (001) crystallographic plane reconstructed from these simulated holograms can show this influence.The incomplete range of azimuth angle causes inhomogeneous brightness of the reconstructed atomic images.The incomplete range of polar angle causes the reconstructed atomic positions slightly shifted toward the central site and the increase of background brightness.The influence of the polar angle step on the reconstructed atomic images can be ignored if the step is enough small.

    HTML

Reference (1)

目录

/

DownLoad:  Full-Size Img  PowerPoint
Return
Return