A simulation study on the measurement of D0-D0 mixing parameter y at BESⅢ

  • We established a method on measuring the D0-D0 mixing parameter y for BESⅢ experiment at the BEPCⅡ e+e collider. In this method, the doubly tagged π(3770) →D0-D0 events, with one D decays to CP-eigenstates and the other D decays semileptonically, are used to reconstruct the signals. Since this analysis requires good e/π separation, a likelihood approach, which combines the dE/dx, time of flight and the electromagnetic shower detectors information, is used for particle identification. We estimate the sensitivity of the measurement of y to be 0.007 based on a 20fb-1 fully simulated MC sample.
  • 加载中
  • [1] . Bigi I I, Uraltsev N. Nucl. Phys. B, 2001, 592: 922. Burdman G, Shipsey I. Ann. Rev. Nucl. and Part. Sci.,2003, 53: 4313. Falk A F, Grossman Y, Ligeti Z. Phys. Rev. D, 2002, 65:0540344. Falk A F, Grossman Y, Ligeti Z, Petrov A A. Phys. Rev.D, 2004, 69: 1140215. Staric Met al (Belle Collaboration). Phys. Rev. Lett., 2007,98: 2118036. Aubert B et al (BABAR Collaboration). Phys. Rev. Lett.,2007, 98: 2118027. ZHANG L M et al (Belle Collaboration). Phys. Rev. Lett.,2007, 99: 1318038. Aaltonen T et al (CDF Collaboration). arXiv:0712.15679. Aubert B et al (BABAR Collaboration). arXiv:0712.224910. Bitenc U et al (Belle Collaboration). arXiv:0802.295211. Aubert B et al (BABAR Collaboration). Phys. Rev. D,2007, 76: 01401812. SUN Yong-Zhao et al. HEP NP, 2007, 31: 423-430 (in Chinese)13. CHENG Xiao-Dong et al. Phys. Rev. D, 2007, 75: 09401914. Asner D M, SUN W M. Phys. Rev. D, 2006, 73: 03402415. Asner D M et al. Int. J. Mod. Phys A, 2006, 21: 545616. Gronau M, Grossman Y, Rosner J L. Phys. Lett. B, 2001,508: 3717. XING Z Z. Phys. Rev. D, 1997, 55: 19618. XING Z Z. Phys. Lett. B, 1996, 372: 31719. LI Wei-Dong, LIU Huai-Min et al. The Offline Software forthe BES0 Experiment. Proceeding of CHEP06. Mumbai,India, 200620. DENG Zi-Yan et al. HEP NP, 2006, 30(5): 371-377(in Chinese)21. Agostinelli S et al. (Geant4 Collaboration). Nucl. Instrum.Methods A, 2003, 506: 25022. BES0 Design Report. Interior Document in Institute of High Energy Physics, 200423. QING Gang et al. HEP NP, 2008, 32(1): 1-824. HU Ji-Feng et al. HEP NP, 2007, 31(10): 893 (in Chinese)25. Harris F A et al (BES Collab.). arXiv:physics/0606059,200626. Bishop C M. Neural Networks for Pattern Recognition. Oxford:Clarendon, 1998; Beale R, Jackson T. Neural Computing:An Introduction. New York: Adam Hilger, 199127. Carli T, Koblitz B. Nucl. Instrum. Methods A, 2003, 501:576-588; Holmstrom L, Sain R, Miettinen H E. Comput.Phys. Commun., 1995, 88: 195
  • 加载中

Get Citation
HUANG Bin, ZHENG Yang-Heng and LI Wei-Dong. A simulation study on the measurement of D0-D0 mixing parameter y at BESⅢ[J]. Chinese Physics C, 2008, 32(12): 945-951. doi: 10.1088/1674-1137/32/12/002
HUANG Bin, ZHENG Yang-Heng and LI Wei-Dong. A simulation study on the measurement of D0-D0 mixing parameter y at BESⅢ[J]. Chinese Physics C, 2008, 32(12): 945-951.  doi: 10.1088/1674-1137/32/12/002 shu
Milestone
Received: 2008-05-29
Revised: 2008-06-11
Article Metric

Article Views(4979)
PDF Downloads(771)
Cited by(0)
Policy on re-use
To reuse of subscription content published by CPC, the users need to request permission from CPC, unless the content was published under an Open Access license which automatically permits that type of reuse.
通讯作者: 陈斌, bchen63@163.com
  • 1. 

    沈阳化工大学材料科学与工程学院 沈阳 110142

  1. 本站搜索
  2. 百度学术搜索
  3. 万方数据库搜索
  4. CNKI搜索

Email This Article

Title:
Email:

A simulation study on the measurement of D0-D0 mixing parameter y at BESⅢ

    Corresponding author: HUANG Bin,

Abstract: We established a method on measuring the D0-D0 mixing parameter y for BESⅢ experiment at the BEPCⅡ e+e collider. In this method, the doubly tagged π(3770) →D0-D0 events, with one D decays to CP-eigenstates and the other D decays semileptonically, are used to reconstruct the signals. Since this analysis requires good e/π separation, a likelihood approach, which combines the dE/dx, time of flight and the electromagnetic shower detectors information, is used for particle identification. We estimate the sensitivity of the measurement of y to be 0.007 based on a 20fb-1 fully simulated MC sample.

    HTML

Reference (1)

目录

/

DownLoad:  Full-Size Img  PowerPoint
Return
Return