×
近期发现有不法分子冒充我刊与作者联系,借此进行欺诈等不法行为,请广大作者加以鉴别,如遇诈骗行为,请第一时间与我刊编辑部联系确认(《中国物理C》(英文)编辑部电话:010-88235947,010-88236950),并作报警处理。
本刊再次郑重声明:
(1)本刊官方网址为cpc.ihep.ac.cn和https://iopscience.iop.org/journal/1674-1137
(2)本刊采编系统作者中心是投稿的唯一路径,该系统为ScholarOne远程稿件采编系统,仅在本刊投稿网网址(https://mc03.manuscriptcentral.com/cpc)设有登录入口。本刊不接受其他方式的投稿,如打印稿投稿、E-mail信箱投稿等,若以此种方式接收投稿均为假冒。
(3)所有投稿均需经过严格的同行评议、编辑加工后方可发表,本刊不存在所谓的“编辑部内部征稿”。如果有人以“编辑部内部人员”名义帮助作者发稿,并收取发表费用,均为假冒。
                  
《中国物理C》(英文)编辑部
2024年10月30日

Simulation study of a photo-injector for brightness improvement in Thomson scattering X-ray source via ballistic bunching

Get Citation
DING Yun-Ze, DU Ying-Chao, ZHANG Zhen and HUANG Wen-Hui. Simulation study of a photo-injector for brightness improvement in Thomson scattering X-ray source via ballistic bunching[J]. Chinese Physics C, 2014, 38(2): 027003. doi: 10.1088/1674-1137/38/2/027003
DING Yun-Ze, DU Ying-Chao, ZHANG Zhen and HUANG Wen-Hui. Simulation study of a photo-injector for brightness improvement in Thomson scattering X-ray source via ballistic bunching[J]. Chinese Physics C, 2014, 38(2): 027003.  doi: 10.1088/1674-1137/38/2/027003 shu
Milestone
Received: 2013-04-25
Revised: 1900-01-01
Article Metric

Article Views(1764)
PDF Downloads(194)
Cited by(0)
Policy on re-use
To reuse of subscription content published by CPC, the users need to request permission from CPC, unless the content was published under an Open Access license which automatically permits that type of reuse.
通讯作者: 陈斌, bchen63@163.com
  • 1. 

    沈阳化工大学材料科学与工程学院 沈阳 110142

  1. 本站搜索
  2. 百度学术搜索
  3. 万方数据库搜索
  4. CNKI搜索

Email This Article

Title:
Email:

Simulation study of a photo-injector for brightness improvement in Thomson scattering X-ray source via ballistic bunching

    Corresponding author: DU Ying-Chao,

Abstract: Increasing the peak brightness is beneficial to various applications of the Thomson scattering X-ray source. A higher peak brightness of the scattered X-ray pulse demands a shorter scattering electron beam realized by beam compression in the electron beam-line. In this article, we study the possibility of compressing the electron beam in a typical S-band normal conducting photo-injector via ballistic bunching, through just adding a short RF linac section right behind the RF gun, so as to improve the peak brightness of the scattered x-ray pulse. Numerical optimization by ASTRA demonstrates that the peak current can increase from 50 A to > 300 A for a 500 pC, 10 ps FWHM electron pulse, while normalized transverse RMS emittance and RMS energy spread increases very little. Correspondingly, the peak brightness of the Thomson scattering X-ray source is estimated to increase about three times.

    HTML

目录

/

DownLoad:  Full-Size Img  PowerPoint
Return
Return