近期发现有不法分子冒充我刊与作者联系,借此进行欺诈等不法行为,请广大作者加以鉴别,如遇诈骗行为,请第一时间与我刊编辑部联系确认(《中国物理C》(英文)编辑部电话:010-88235947,010-88236950),并作报警处理。
本刊再次郑重声明:
(1)本刊官方网址为cpc.ihep.ac.cn和https://iopscience.iop.org/journal/1674-1137
(2)本刊采编系统作者中心是投稿的唯一路径,该系统为ScholarOne远程稿件采编系统,仅在本刊投稿网网址(https://mc03.manuscriptcentral.com/cpc)设有登录入口。本刊不接受其他方式的投稿,如打印稿投稿、E-mail信箱投稿等,若以此种方式接收投稿均为假冒。
(3)所有投稿均需经过严格的同行评议、编辑加工后方可发表,本刊不存在所谓的“编辑部内部征稿”。如果有人以“编辑部内部人员”名义帮助作者发稿,并收取发表费用,均为假冒。
                  
《中国物理C》(英文)编辑部
2024年10月30日

Evaluation of imaging protocol for ECT based on CS image reconstruction algorithm

Get Citation
ZHOU Xiao-Lin, YUN Ming-Kai, CAO Xue-Xiang, LIU Shuang-Quan, WANG Lu, HUANG Xian-Chao and WEI Long. Evaluation of imaging protocol for ECT based on CS image reconstruction algorithm[J]. Chinese Physics C, 2014, 38(4): 048201. doi: 10.1088/1674-1137/38/4/048201
ZHOU Xiao-Lin, YUN Ming-Kai, CAO Xue-Xiang, LIU Shuang-Quan, WANG Lu, HUANG Xian-Chao and WEI Long. Evaluation of imaging protocol for ECT based on CS image reconstruction algorithm[J]. Chinese Physics C, 2014, 38(4): 048201.  doi: 10.1088/1674-1137/38/4/048201 shu
Milestone
Received: 2013-06-28
Revised: 2013-11-20
Article Metric

Article Views(2132)
PDF Downloads(220)
Cited by(0)
Policy on re-use
To reuse of subscription content published by CPC, the users need to request permission from CPC, unless the content was published under an Open Access license which automatically permits that type of reuse.
通讯作者: 陈斌, bchen63@163.com
  • 1. 

    沈阳化工大学材料科学与工程学院 沈阳 110142

  1. 本站搜索
  2. 百度学术搜索
  3. 万方数据库搜索
  4. CNKI搜索

Email This Article

Title:
Email:

Evaluation of imaging protocol for ECT based on CS image reconstruction algorithm

    Corresponding author: WEI Long,

Abstract: Single-photon emission computerized tomography and positron emission tomography are essential medical imaging tools, for which the sampling angle number and scan time should be carefully chosen to give a good compromise between image quality and radiopharmaceutical dose. In this study, the image quality of different acquisition protocols was evaluated via varied angle number and count number per angle with Monte Carlo simulation data. It was shown that, when similar imaging counts were used, the factor of acquisition counts was more important than that of the sampling number in emission computerized tomography. To further reduce the activity requirement and the scan duration, an iterative image reconstruction algorithm for limited-view and low-dose tomography based on compressed sensing theory has been developed. The total variation regulation was added to the reconstruction process to improve the signal to noise Ratio and reduce artifacts caused by the limited angle sampling. Maximization of the maximum likelihood of the estimated image and the measured data and minimization of the total variation of the image are alternatively implemented. By using this advanced algorithm, the reconstruction process is able to achieve image quality matching or exceed that of normal scans with only half of the injection radiopharmaceutical dose.

    HTML

目录

/

DownLoad:  Full-Size Img  PowerPoint
Return
Return