Error analysis and lattice improvement for the C-ADS Injector-Ⅰ
- Received Date: 2013-07-31
- Accepted Date: 1900-01-01
- Available Online: 2014-06-05
Abstract: The injector Scheme-Ⅰ (or Injector-Ⅰ) of the C-ADS linac is a 10 mA 10 MeV proton linac working in CW mode. It is mainly comprised of a 3.2 MeV room-temperature 4-vane RFQ and twelve superconducting single-spoke cavities housed in a long cryostat. Error analysis including alignment and field errors, and static and dynamic ones for the injector are presented. Based on detailed numerical simulations, an orbit correction scheme has been designed, which shows that with correction the rms residual orbit errors can be controlled within 0.3 mm and a beam loss rate of 1.7× 10-6 is obtained. To reduce the beam loss rate further, an improved lattice design for the superconducting spoke cavity section has been studied.





Abstract
HTML
Reference
Related
PDF












DownLoad: