Performance evaluation of BPM system in SSRF using PCA method

  • The beam position monitor (BPM) system is of most importance in a light source. The capability of the BPM depends on the resolution of the system. The traditional standard deviation on the raw data method merely gives the upper limit of the resolution. Principal component analysis (PCA) had been introduced in the accelerator physics and it could be used to get rid of the actual signals. Beam related information was extracted before the evaluation of the BPM performance. A series of studies had been made in the Shanghai Synchrotron Radiation Facility (SSRF) and PCA was proved to be an effective and robust method in the performance evaluations of our BPM system.
      PCAS:
  • 加载中
  • [1] Irwin J, WANG C X, YAN Y T, et al. Physical Review Letters, 1999, 8: 1684-1687[2] WANG Chun-Xi. Physical Review Special Topics-Accelerators and Beams, 2004, 7: 114001[3] WANG Chun-Xi, Rama Calaga. Proceedings of EPAC 2004, 2004. 1470-1472[4] WANG Chun-Xi. Proceedings of EPAC 2004, 2004: 1473-1475[5] Calaga R, Tomás R. Physical Review Special Topics-Accelerators and Beams, 2004, 7: 042801[6] WANG Chun-Xi, Michael Borland, Vadim Sajaev et al. Proceedings of the 2001 Particle Accelerator Conference, 2001. 1354-1356[7] Wolski A, Ross M C. Proceedings of EPAC 2002, 2002. 1205-1207[8] WANG Chun-Xi. Proceedings of the 2003 Particle Accelerator Conference. 2003. 3407-3409[9] WANG Chun-Xi. Proceedings of the 2003 Particle Accelerator Conference. 2003. 3410-3412[10] WANG Chun-Xi, Vadim Sajaev, YAO Chih-Yuan. Physical Review Special Topics-Accelerators and Beams, 2003, 6: 104001
  • 加载中

Get Citation
CHEN Zhi-Chu, LENG Yong-Bin, YAN Ying-Bing, YUAN Ren-Xian and LAI Long-Wei. Performance evaluation of BPM system in SSRF using PCA method[J]. Chinese Physics C, 2014, 38(7): 077004. doi: 10.1088/1674-1137/38/7/077004
CHEN Zhi-Chu, LENG Yong-Bin, YAN Ying-Bing, YUAN Ren-Xian and LAI Long-Wei. Performance evaluation of BPM system in SSRF using PCA method[J]. Chinese Physics C, 2014, 38(7): 077004.  doi: 10.1088/1674-1137/38/7/077004 shu
Milestone
Received: 2013-08-30
Revised: 1900-01-01
Article Metric

Article Views(3409)
PDF Downloads(213)
Cited by(0)
Policy on re-use
To reuse of subscription content published by CPC, the users need to request permission from CPC, unless the content was published under an Open Access license which automatically permits that type of reuse.
通讯作者: 陈斌, bchen63@163.com
  • 1. 

    沈阳化工大学材料科学与工程学院 沈阳 110142

  1. 本站搜索
  2. 百度学术搜索
  3. 万方数据库搜索
  4. CNKI搜索

Email This Article

Title:
Email:

Performance evaluation of BPM system in SSRF using PCA method

    Corresponding author: CHEN Zhi-Chu,
    Corresponding author: LENG Yong-Bin,

Abstract: The beam position monitor (BPM) system is of most importance in a light source. The capability of the BPM depends on the resolution of the system. The traditional standard deviation on the raw data method merely gives the upper limit of the resolution. Principal component analysis (PCA) had been introduced in the accelerator physics and it could be used to get rid of the actual signals. Beam related information was extracted before the evaluation of the BPM performance. A series of studies had been made in the Shanghai Synchrotron Radiation Facility (SSRF) and PCA was proved to be an effective and robust method in the performance evaluations of our BPM system.

    HTML

Reference (1)

目录

/

DownLoad:  Full-Size Img  PowerPoint
Return
Return