Abstract: X-band accelerators for multi-bunches are a new way to produce high luminosity and energy efficiency bunches. The smaller the size and the more bunches, the more severe is the wakefield in the X-band accelerators, unless some means of strongly suppressing the transverse wakefield is adopted in the design of the accelerating structure. Here, the derivation of the wakefield function of the double circuit model and its application to the designed accelerator structure have been demonstrated.