Abstract:
Beam Position Monitors (BPMs) for the low-β beam of the Chinese Accelerator Driven Subcritical system (CADS) Proton linac are of the capacitive pick-up type. They provide higher output signals than that of the inductive type. This paper will describe the design and tests of the capacitive BPM system for the low-β proton linac, including the pick-ups, the test bench and the read-out electronics. The tests done with an actual proton beam show a good agreement between the measurements and the simulations in the time domain.
-
-
References
|
[1]
|
Y. He, et al, in Proceedings of IPAC (Spain, 2011) p. 2613 |
|
[2]
|
R. E. Shafer, AIP Conf. Proc., 212: 26 (1990) |
|
[3]
|
S. R. Smith, AIP Conf. Proc., 390: 50 (1997) |
|
[4]
|
T. Suwada et al, Nucl. Instrum. Methods A, 440: 307 (2000) |
|
[5]
|
T. Suwada, Nucl. Instrum. Methods A, 705: 7 (2013) |
|
[6]
|
N. Hayashi et al, Nucl. Instrum. Methods A, 677: 94 (2012) |
|
[7]
|
M. Bai et al, Nucl. Instrum. Methods A, 499: 372 (2003) |
|
[8]
|
P. Forck et al, Beam Position Monitors, in CERN Accelerator School on Beam Diagnostics, (2008) |
|
[9]
|
R. E. Shafer, in Proc. Beam Instr. Workshop (BIW), (Santa Fe 1993) p.303 |
|
[10]
|
M. Cohen-Solal, Phys. Rev. Spec. TOP - AC, 13: 032801 (2010) |
|
[11]
|
P. Strehl, Beam instrumentation and diagnostics (Berlin: Springer, 2006) p.156 |
|
[12]
|
P. Kowina et al, in Proceedings of DIPAC (Basel, Switzerland, 2009) p.35 |
|
[13]
|
www.cst.com |
|
[14]
|
Y. F. Ruan et al, Chinese Phys. C, 33(3): 240-244 (2009) |
|
[15]
|
User Manual, Libera Single Pass H, www. i-tech.si, (2013) |
-
-
Access
-
-