-
The extraction of pulse shape information involves three steps: (1) for denoising, we performed a triple moving average with a 0.05-μs window (5 sampling points for the 100-MHz sampling rate) on the fast amplifier pulse; (2) the maximum amplitude of the denoised pulse was used for energy calibration; and (3) the current pulse was extracted from the denoised pulse by using a differential filter, and the maximum amplitude of the current pulse (A) was used in the subsequent A/E method.
The pulse information extraction process is illustrated in Fig. 1. The moving-average filtering with a window width of 50 ns was performed three times on the original pulse according to Eq. (1), where
$ P_k^{(n)} $ denotes the amplitude of the k-th sampling point of the pulse after n iterations and$ L=5 $ (10 ns for each point) denotes the width of the moving-average window. The maximum amplitude was utilized for energy calibration.Figure 1. (color online) Pulse information extraction process; (a) single-site event, (b) multisite event, (c) high A/E event, and (d) n+ event. The energies of the events in the four figures are 2102.6, 2008.4, 2054.3, and 2012.5 keV, respectively.
$ P_i^{(n)} = \begin{cases} \dfrac{1}{L} \displaystyle\sum\nolimits_{k=i-L+1}^{k=i} P_k^{(n-1)} & i \geq {L-1}, \\ \dfrac{1}{i+1} \displaystyle\sum\nolimits_{k=0}^{k=i} P_k^{(n-1)} & i < {L-1}\end{cases} $
(1) The current pulse was extracted from the denoised pulse by using a differential filter Eq. (2), where
$ L=5 $ denotes the differential step size. Parameter A/E was defined as the ratio of the maximum current amplitude (A) to the reconstructed energy (E).$ I_i = \begin{cases} P_i^{(3)}-P_{i-L}^{(3)} & i \geq {L}, \\ 0 & i < {L}\end{cases} $
(2) Between runs IV and V of data acquisition, we disassembled the external shields of the CDEX-1B detector, removed the NaI detector, and conducted a calibration experiment with a 228Th radiation source. Figure 2 shows the energy calibration result. We selected eight gamma rays of 238.63 keV (208Tl), 583.19 keV (208Tl), 727.33 keV (212Bi), 860.56 keV (208Tl), 1592.50 keV (208Tl), 1620.50 keV (212Bi), 2104.50 keV (208Tl single-escape peak), and 2614.51 keV (208Tl) energies for energy calibration and used a cubic polynomial function to reduce the residuals of the calibrated energy [33]. After correction, the maximum residual was less than 0.1 keV. After the calibration, the external shield and NaI detector were restored to their original states.
Figure 2. (color online) (Top) Linear relationship between the calibrated energy and real energy. (Middle) Residual of the calibrated energy with respect to real energy. The residual was fitted using a cubic polynomial, and the fitting results are used to correct the linear calibrated results. (Bottom) Corrected residual; the horizontal axis represents real energy. After correction, the corrected residual was less than 0.1 keV.
We should emphasize that the calibrated energy in this study was only used to evaluate energy resolution and A/E cut parameters. The same calibration method was applied to each exposure dataset separately to guarantee the stability of calibration during the long-term operation, with five energy peaks in the low background spectrum: 238.63 keV (208Tl), 583.19 keV (208Tl), 1460.75 keV (40K), 1764.49 keV (214Bi), and 2614.51 keV (208Tl). The corrected residual was maintained below 0.2 keV.
The
$ {0\nu\beta\beta} $ process only emits two electrons, and the range of these two electrons in a germanium crystal is approximately 1 mm. Therefore, most of the energy of a$ {0\nu\beta\beta} $ event will be deposited in a point-like region, and$ {0\nu\beta\beta} $ event is regarded as an SSE. The majority of the background events are multisite events (MSE), such as the multiple Compton scattering events. Thus, distinguishing SSEs from MSEs and discarding MSEs as background events, the background level in the signal region can be effectively reduced. For the MSE, as the energy is deposited in multiple spatial points, the multiple charge carrier clusters will reach the P+ point contact at different times. However, an SSE with equivalent energy comprises only one carrier cluster, and the maximal current amplitude, generated when the hole carrier cluster reaches the P+ point contact, is higher than that of the MSE. Therefore, we can identify the nature of the event, i.e., SSE or MSE, based on the ratio of the maximal current value A to the energy E of the event (A/E) [34–36]. Additionally, certain events exhibited higher A/E values with respect to typical SSEs, which are referred to as high A/E events. These types of events can be segmented into two types according to their origin. First, the events occur proximate to the point electrode, during which the hole carriers will reach the P-point electrode in an extremely short period and generate a current peak. At this instant, the electron carriers are still drifting, and the current signal generated by the electrons will be superimposed on the current peak, thereby increasing the maximal current value. Then, the event occurs proximate to the passivation layer. In this event, the trajectory of charge carrier holes passes through the surface region near the passivation layer, where the gradient of the weight potential field is larger, thereby leading to a higher A/E value in the induced signal pulse [35, 37, 38]. These two types of events constitute high A/E events. Figure 3 shows the A/E distribution of 228Th calibration events in an energy interval of [1745 keV, 1775 keV], and the A/E distributions of the three abovementioned types of events are illustrated in different colors.Figure 3. (color online) A/E distribution of 228Th calibration events in energy intervals of [1745 keV, 1775 keV], including three major components: MSEs, SSEs, and high A/E events. The A/E values of multiple components follow different distribution forms, and the A/E of the SSEs follows the Gaussian distribution. Dashed lines denote the fitting result of the A/E distribution using Eq. (3); green, red, and blue shadows represent the MSE, SSE, and high A/E event components, respectively.
The A/E distribution of events pertaining to a specific energy interval can be described by three components (SSE, MSE, and high A/E):
$ \begin{aligned}[b] f(x)=\;&\frac{n}{\sigma \cdot \sqrt{2\pi}} \cdot \exp{\left(-\frac{(x-\mu)^2}{2\sigma^2}\right)}\\ & + m \cdot \frac{ \exp{(f \cdot (x-l))}+d}{\exp \left(\dfrac{x-l}{t}+h \right)} +a\cdot \sqrt{x-b}, \end{aligned} $
(3) where the three terms correspond to the three components, and the distribution of the first two terms follows Refs. [34, 35]. Furthermore, μ and σ of events in various energy intervals were fitted using Eq. (3). The energy dependence of μ and σ is depicted in Fig. 4. The A/E values across nine energy intervals (gray shadow regions in Fig. 4) were fitted to obtain corresponding μ and σ. Thereafter, these μ and σ values are fitted with the energies (midpoints of energy interval), and the energy dependence of the two parameters is depicted in Fig. 5. For an event with energy E, if its A/E value satisfies
$\mu(E)-4\sigma(E) < A/E <\mu(E)+4\sigma(E)$ , it will be regarded as an SSE and retained in the A/E cut. Fig. 6 illustrates the distribution of A/E vs Energy of exposure data from runs IV and V.Figure 4. (color online) Two-dimensional distribution diagram of A/E vs. the energy of the 228Th calibration data. The upper and lower red dashed lines correspond to
$ \mu(E)+4\sigma(E) $ and$ \mu(E)-4\sigma(E) $ threshold, respectively. The SSEs exhibit a band distribution that decreases gradually with the energies. The major component of the double escape peak (DEP; 1592.50 keV) of 2614.51 keV γ-rays (208Tl) is considered as SSE. Hence, the events are primarily between the two dashed lines. The main component of the single escape peak (SEP; 2103.51 keV) is deemed as MSE, and thus the events are mainly outside the two dashed lines. The selection of fitting energy intervals (9 gray shadow bands in the figure) is basically equidistant, avoiding the omnipotent peaks, single escape peaks, and double escape peaks of different γ-rays, because the main component of the backgrounds in the region of interest (ROI) is attributed to Compton events.Figure 5. (color online) A/E distribution parameters μ and σ of SSE in nine energy intervals were fitted with respect to energy. Furthermore, μ(E) used quadratic curve fitting, wheseas σ(E) used linear fitting, both of which were used to set the SSE/MSE discrimination threshold.
Figure 6. (color online) Two-dimensional distribution diagram of A/E vs Energy of exposure data from runs IV and V. Red dashed lines denote the cut threshold.
We monitored the survival fraction (SF) of the A/E cut in 1800–2200 keV energy region to evaluate the stability of the cut. A flat line was applied to fit SF via the least square method. The
$ \chi^2 $ /(degree of freedom) of the fit is 14.93/18, which can confirm the stability of the A/E parameters over long-term detector operation.As
$ {0\nu\beta\beta} $ events are SSEs, the energy resolution in the signal region was evaluated after A/E discrimination. Specifically, four energy peaks with sufficient statistic were selected from the 228Th calibration data, and their resolutions were fitted with respect to energy using a linear function to obtain the resolution at$ Q_{\beta\beta} $ shown in Fig. 7. These four energy peaks correspond to 860.56 keV (208Tl), 1592.50 keV (208Tl), 1620.50 keV (212Bi), and 2614.51 keV (208Tl). The FWHMs of the four peaks are fitted with a function FWHM =$ a+bE $ , and the interpolation of FWHM at 2039 keV is 2.76 keV. Uncertainties of the result were derived from two aspects via the following procedure: the resolution was linearly fitted with various combinations of three of the four aforementioned γ peaks, and the maximum deviation in the interpolated resolution at$ Q_{\beta\beta} $ was accounted as a systematic uncertainty. The statistical uncertainty of FWHM at$ Q_{\beta\beta} $ was calculated using the covariance matrix of the linear fit parameters ($ a, b $ ). By combining both uncertainties, the energy resolution of SSEs at$ Q_{\beta\beta} $ was derived as$ 2.76\pm0.13 $ keV.Figure 7. (color online) Energy resolution of single-site events at
$ Q_{\beta\beta} $ derived from the 228Th calibration data. The linear fitting of the resolution was preformed with different combinations of three of the four aforementioned γ peaks, and the maximum deviation at$ Q_{\beta\beta} $ (0.11 keV) was counted as a systematic uncertainty. Uncertainty introduced by the parameters of the fitting results (0.06 keV) are considered as statistical uncertainty. The energy resolution of single-site events from exposure data is also shown for comparison.The CDEX-1B detector was enveloped by a NaI(Tl) anti-coincidence detector, and NaI(Tl) crystal was processed into a thick-walled well structure. During the detector operation, the low-temperature cryostat of the PPCGe detector was placed in the well [24]. For the PPCGe detector, the enclosed solid angle was proximate to 4π, resulting in a relatively high anti-coincidence efficiency [24]. As the background events in the region of interest (ROI) are primarily composed of Compton scattering events, there exists a high probability of depositing energy outside the detector. The anti-coincidence detector exhibited a strong coincident ability for background events in the high-energy region and reduced the background level in the ROI by nearly an order of the magnitude.
As depicted in Fig. 8, the background level in ROI is suppressed from 7.7 to 0.33 counts/(keV
$ \cdot $ kg$ \cdot $ yr). This corresponds to a 23-fold reduction, achieved through anti-coincidence (AC) and A/E cuts.Figure 8. (color online) Energy spectra of the CDEX-1B detector (500–2800 keV, 504.3 kg
$ \cdot $ day); the shadow band represents the signal region of 76Ge$ Q_{\beta\beta} $ . The region of interest (ROI) background level before the anti-coincidence and MSE/SSE cut was approximately 7.7 counts/(keV$ \cdot $ kg$ \cdot $ yr). After the anti-coincidence (AC) cut, the ROI background level decreased by nearly one order of magnitude. After the AC and MSE/SSE cuts, the magnitude of the ROI background level was 0.33 counts/(keV$ \cdot $ kg$ \cdot $ yr). The combination of these two cuts significantly suppressed on the background.Previous calibration experiments demonstrated that the dead-layer thickness of the CDEX-1B detector was
$ 0.88\pm 0.12 $ mm [32]. The energy of a$ {0\nu\beta\beta} $ event occurring at the edge of the detector (near the dead layer) may not be fully collected, thereby reducing the detection efficiency of$ {0\nu\beta\beta} $ events. To calculate the efficiency, we used Geant4 for simulating the$ {0\nu\beta\beta} $ events in the CDEX-1B germanium crystal and sampled the emission directions as well as the energies of the two electrons according to the following Eq. (4) [39]:$ \begin{aligned}[b] F(T_1,T_2,\cos{\theta})=\;&(T_1+1)^2(T_2+1)^2\\&\times \delta (T_0-T_1-T_2)(1-\beta_1\beta_2\cos{\theta}), \end{aligned} $
(4) $ \beta_i=\frac{\sqrt{T_i(T_i+2)}}{T_i+1}, $
(5) where
$ T_0 $ denotes$ Q_{\beta\beta} $ ,$ T_i $ indicates the electron kinetic energy, and θ represents the angle between the emission directions of two electrons. The proportion of$ {0\nu\beta\beta} $ event with complete energy deposition (at the energy range of$ Q_{\beta\beta} \pm{3\sigma} $ ) can be calculated as$ (84.8\pm{0.8}) $ %.The
$ {0\nu\beta\beta} $ signal survival efficiency of the MSE/SSE discrimination is a key parameter. Theoretically,$ {0\nu\beta\beta} $ events are uniformly distributed in the detector crystal. The 228Th radiation source used in the calibration experiment is a point-like source external to the Ge crystal, resulting in a non-uniform distribution of the induced double escape peak (DEP) events. Particularly, given that we put the source close to the electrode surface, where the gradient of weight potential field is large, the fraction of high A/E DEP events is very high, which leads to a low survival efficiency. Therefore, the survival efficiency of$ {0\nu\beta\beta} $ events cannot be directly derived from the calibration data. Consequently, we applied a simulation method [18], the accuracy of which was verified by the calibration data.The simulation included three steps:
● Simulation of energies and positions using Geant4 software [40].
● Simulation of the carrier drift processes and the pulses generated through the pulse shape simulation package in SAGE [41] based on the Shockley-Ramo theory [42]. These original pulses were convolved with electronics response function, which was obtained by inputting a δ-like current pulse with a very fast rising edge into the amplifier chain. The noise in the experimental pulses was superimposed onto the simulated pulse.
● Extraction of energy and A/E parameters in simulated pulses via the aforementioned pulse-processing procedures.
As illustrated in Fig. 9, the A/E distributions of the simulated events in different energy intervals are in good agreement with the calibration data. The survival rates of DEP, FEP, and SEP events in Fig. 9 under the
$ 3\sigma $ ,$ 4\sigma $ , and$ 5\sigma $ cut thresholds are compared with the experimental results presented in Table 1. The difference of DEP ($ \pm $ 3.8%) was considered as a systematic uncertainty. The same method was used to simulate the A/E distribution of the$ {0\nu\beta\beta} $ events, which were uniformly distributed in the Ge crystal. Finally, the proportion of$ {0\nu\beta\beta} $ events passing the A/E cut (A/E cut survival efficiency of$ {0\nu\beta\beta} $ events) was calculated as$ (78.6\pm 3.8) $ %.Figure 9. (color online) (Top) Calibration and normalized simulated spectra of 228Th. Shadow bands include four distinct types of energy regions: double escape peak (DEP, 1592.5 keV), full energy peak (FEP, 1620.5 keV), Compton continuum (CC, 1860.0 keV), and single escape peak (SEP, 2103.5 keV). Calibration and simulated A/E distributions were compared in these energy regions. (Bottom) Simulated A/E distributions (after normalization, the center value of SSE distribution is 1) of 228Th are consistent with the corresponding calibration data. The difference between the DEP's cut efficiencies of the simulated data and calibration data was regarded as a systematic uncertainty of the A/E cut survival efficiency of
$ {0\nu\beta\beta} $ events.Event Cut threshold Calibration(%) Simulation Diff.(%) Uncertainty $ 3 \sigma $ 46.38 51.00 4.62 DEP $ 4 \sigma $ 49.17 52.56 3.39 3.8 $ 5 \sigma $ 51.15 54.36 3.22 $ 3 \sigma $ 17.72 24.75 7.03 FEP $ 4 \sigma $ 20.22 29.06 8.84 8.5 $ 5 \sigma $ 22.21 31.73 9.50 $ 3 \sigma $ 13.54 17.83 4.29 SEP $ 4 \sigma $ 15.88 21.10 5.22 5.3 $ 5 \sigma $ 17.75 24.17 6.42 Table 1. Comparison of A/E cut efficiency for DEP, FEP, and SEP events between calibration and pulse shape simulation.
Moreover, the CDEX-1B detector was equipped with a pulsed reset preamplifier. The preamplifier resets after the voltage reaches the threshold owing to the continuous and stable leakage current. The charge collection of each event decreases the voltage, and the decreased amplitude is directly proportional to the collected charge (corresponding to the event energy) [10]. Events with higher energy are more likely to decrease the voltage to reach the threshold, and thereby, resetting the amplifier. These types of events are measured with degraded energy and have been excluded from the analysis. Under the low counting rate condition (
$ \sim $ 1 count/period), the detection efficiency can be expressed as follows:$ \eta(E)= 1- \frac{E}{E_s-E_s\cdot \dfrac{T_{\rm veto}}{T_0}} \approx 1-\frac{E}{E_s} \left(\frac{T_{\rm veto}}{T_0}\ll 1 \right), $
(6) where E denotes the energy of the event and
$ E_s $ denotes the saturation energy of the preamplifier. Any event with energy$ E_s $ will cause a voltage decrease equal to the voltage decrease during a entire period of preamplifier. In this study,$ E_s $ was evaluated as 4.7 MeV. A period of a few milliseconds exists after a reset during which the baseline is distorted. Specifically,$T_{\rm veto}$ =10 ms is a preset time window to veto the signals in this period, and$ T_0\approx $ 620 ms is the reset period if there is no signal in the period. Upon fitting the data during the entire operation time, the efficiency at$ {0\nu\beta\beta} $ $ Q_{\beta\beta} $ energy was (56.6$ \pm{} $ 0.1)%. -
By using a total of 504.3 kg
$ \cdot $ day effective exposure data, the energy interval of [1989 keV, 2089 keV] was selected to analyze the half-life of 76Ge$ {0\nu\beta\beta} $ (Fig. 11). The relationship between the expected signal count,$ \mu_s $ , and half-life$ {T_{1/2}^{0\nu}}{} $ can be determined as follows:Figure 11. (color online) Physical results of the 76Ge
$ {0\nu\beta\beta} $ analysis from the CDEX-1B experiment. (Top) Energy spectrum in the energy interval of [1989 keV, 2089 keV] with a bin width of 2 keV, where no peak from the background is observed, and a flat background is assumed. Shadow interval denotes the FWHM energy region of [2037.6 keV, 2040.4 keV]. (Bottom) Best-fit result of the background level and its 68% confidence interval (Poisson distribution). The blue Gaussian peak represents the signal strength of the 90% confidence level, corresponding to the lower limit of$ {0\nu\beta\beta} $ half-life,$ T_{1/2}^{0\nu}\ > \ {1.0}\times 10^{23}\ \rm yr\ (90{\text{%}} \ C.L.) $ . Each thin red line indicates a single event in the energy region after analysis cuts.$ \mu_{s} = \frac{1}{T_{1/2}^{0\nu}} \cdot \frac{N_A \cdot \ln{2} }{m}\cdot \epsilon \cdot n \cdot \eta, $
(7) where
$ N_A $ denotes the Avogadro's constant, m represents the molar mass of natural Ge,$ \epsilon $ indicates the exposure (504.3 kg$ \cdot $ day), n denotes the 76Ge abundance (7.83%), and η represents the total efficiency of detecting$ {0\nu\beta\beta} $ events, which is a product of the inhibit efficiency ($ (56.6\pm{0.1}){\text{%}} $ ), anti-coincidence efficiency ($ 99.8{\text{%}} $ ), MSE/SSE cut efficiency ($ (78.6\pm{3.8}){\text{%}} $ ), and$ {0\nu\beta\beta} $ event energy complete deposition ratio ($ (84.8\pm{0.8}){\text{%}} $ ).Based on the assumption of the flat background in the ROI, the expected background count of the analyzed region can be determined as follows:
$ \mu_{b}=B \cdot \Delta E \cdot \epsilon, $
(8) where
$ \Delta E = 100 $ keV, and B represents the background index (counts/(keV$ \cdot $ kg$ \cdot $ yr)).After comprehensive analysis cuts, only 46 events remained in the analyzed energy region. Accordingly, the extended likelihood function was utilized based on the unbinned method for analysis [43, 44]. The likelihood function is formulated as
$ \begin{aligned}[b] L(S,B) =\;& \frac{(\mu_s+\mu_b)^N {\rm e}^{-(\mu_s+\mu_b)}}{N!}\\&\times \prod_{i=1}^{N} \frac{1}{\mu_s+\mu_b} \left(\frac{\mu_b}{\Delta E}+\frac{\mu_s}{\sqrt{2\pi}\sigma} {\rm e}^{-\frac{(E_i-Q_{\beta\beta}-\delta_{E})^2}{2\sigma^2}}\right), \end{aligned} $
(9) where
$ E_i $ denotes the energy of the i-th event,$ \delta_{E} $ is a possible systematic energy offset at$ Q_{\beta\beta} $ ,$ \mu_s $ is the expected observed signal event number,$ \mu_b $ is the expected background event number, N is the observed event number, and$ \sigma={\rm{FWHM/(2\sqrt{2ln2}})} $ is the energy resolution of SSEs in the ROI. As predicted by the background model, a flat background was assumed in the analyzed region. For the signal, a Gaussian distribution centered at the$ Q_{\beta\beta} $ with a width corresponding to the energy resolution was considered.The constraints on the signal number were derived using frequentist analysis and a two-side test statistic [43, 45]:
$ t_S=-2\ln{\frac{L(S,\hat{\hat{B}})}{L(\hat{S},\hat{B})}}, $
(10) where S denotes the strength of a possible
$ {0\nu\beta\beta} $ signal:$ S= 1/T_{1/2}^{0\nu} $ , corresponding to the expected event number$ \mu_s $ , and$ \hat{\hat{B}} $ denotes the background index obtained by maximizing L when S is fixed. Parameters$ \hat{S} $ and$ \hat{B} $ correspond to the global maximum L. The unbinned profile likelihood analysis yields a best-fit background of$ \hat{B}=0.33 $ counts/(keV$ \cdot $ kg$ \cdot $ yr) and signal strength of$ \hat{S}=0 $ yr$ ^{-1} $ indicating no signal. Accordingly, we selected a discrete set of$ S\in \{S_j\} $ for simulation. For each$ S_j $ , multiple Monte Carlo simulations were performed in combination with other experimental parameters. Furthermore,$ t_{S_j} $ was calculated using the obtained energy spectrum, and its probability distribution$ f(t_s|S_j) $ was obtained through repeated simulations [43]. The$ t_{obj} $ value was calculated using the experimental energy spectrum. The P value of$ S_j $ and observed data were calculated as follows:$ P_{S_j}=\int_{t_{obs}}^{\infty}f(t_s|S_j){\rm{d}} (t_{S_j}). $
(11) The lower limit for 76Ge
$ {0\nu\beta\beta} $ half-life corresponding to$ P=0.1 $ is set to:$ T_{1/2}^{0\nu}\ > \ {1.0}\times 10^{23}\ \rm yr\ (90{\text{%}} \ C.L.). $
(12) The expectation of the experimental sensitivity was evaluated based on the distribution of
$ P_{S_j} $ which was derived from Monte Carlo generated data sets assuming no$ {0\nu\beta\beta} $ signal ($ S=0 $ ) [43]. The median sensitivity was calculated as$ 5.6\times10^{22} $ yr (90% C.L.). The probability of obtaining a limit stronger than the actual limit is 31%.The upper limit of
$ {0\nu\beta\beta} $ signal strength corresponding to the above half-life ($ 1.0\times10^{23} $ yr) is 2.28 events. The energy resolution ($ 2.76 \pm 0.13$ keV) is considered by folding it into the profile likelihood function through additional nuisance parameters constrained by Gaussian probability distribution. Uncertainty of the overall efficiency (37.6±1.9%) is considered by propagating it through Eq. (7). The overall effect of the uncertainty on the half-life limit is 4.9%. We used Eq. (13) to convert the limit on$ T_{1/2}^{0\nu} $ to the limits on effective Majorana neutrino mass,$ \langle m_{\beta\beta}\rangle $ :$ \langle m_{\beta\beta}\rangle=\frac{m_e}{|g_A^2\cdot M^{0\nu}|\cdot \sqrt{T_{1/2}^{0\nu}\cdot G^{0\nu}}}, $
(13) where the phase space factor
$ G^{0\nu} $ for 76Ge is${2.36}\times 10^{-15}\ \mathrm{yr}^{-1}$ [46], and the coupling constant$ g_A = 1.27 $ [2]. Given the values of nuclear matrix element$ M^{0\nu} $ , calculated using different theoretical models, differ considerably, we regarded it as an interval, with a range of 2.66–6.34, selected from Refs. [47–55]. The upper limit on the effective Majorana neutrino mass obtained in this study corresponds to$ \langle m_{\beta\beta}\rangle < $ 3.2–7.5 eV (90% C.L.). -
In this study, we explored the use of a PPCGe in the CDEX-1B experiment for 76Ge
$ {0\nu\beta\beta} $ decay detection. The PPCGe detector is originally designed for dedicated low-energy dark matter searches. However, we upgraded its preamplifier and applied the PSD and anti-veto background suppression technologies to suit the search for$ {0\nu\beta\beta} $ signal.The CDEX-1B PPCGe detector realized an energy resolution of 2.8 keV in the
$ {0\nu\beta\beta} $ signal region, a 23-fold background reduction using PSD and anti-veto, a smooth operation of over 500 days, and provided a 76Ge$ {0\nu\beta\beta} $ decay half-life limit of$ 1.0\times10^{23}\ \mathrm{yr} $ (90% C.L.). These performances exceeded the previous CDEX$ {0\nu\beta\beta} $ studies [10, 11] (as in Table 2) and demonstrated that the PPCGe detectors designed for dark matter search could be used in future large-scale$ {0\nu\beta\beta} $ experiments.CDEX-1B (This work) CDEX-1A BEGe experiment Exposure (kg $ \cdot $ day)504.3 304 186.4 Energy resolution (keV, FWHM@ $ Q_{\beta\beta} $ )$ 2.76\pm0.13 $ $ 4.3 \pm0.2 $ $ 2.85 \pm0.48 $ Efficiency 37.7% 68.4% 73.2% Background index (counts/(keV $ \cdot $ kg$ \cdot $ yr))$ 0.33\pm0.05 $ 4.38 $ 2.35\pm 0.11 $ $ T_{1/2}^{0\nu} $ limit (90% C.L.)$ 1.0\times 10^{23} \mathrm{yr} $ $ 6.4\times 10^{22} \mathrm{yr} $ $ 5.6\times 10^{22} \mathrm{yr} $ We noted that the current background is approximately at the level of dedicated
$ {0\nu\beta\beta} $ experiments using HPGe detector in the late 80s of last century [56], still far from the state-of-art [2] and requirement of future experiments. The background model shows radionuclides in 238U and 232Th decay chains, and they are the primary sources of background in the$ {0\nu\beta\beta} $ signal region. These sources are mainly from the surrounding materials. Therefore, a stringent material screening is crucial for future low-background experiments.The next-generation CDEX
$ {0\nu\beta\beta} $ project, CDEX-300ν, targets at searching$ {0\nu\beta\beta} $ signal at the inverted hierarchy (IH) region with a sensitivity reaching the bottom of the IH region (Fig. 12). The CDEX-300ν will operate approximately 225 kg of enriched germanium detectors (76Ge abundance > 86%) coupled with a liquid argon (LAr) system serving as the cooling medium and veto detector at CJPL [11]. All materials used in detector structure and experiment construction will be screened to control their backgrounds. Furthermore, in light of the enhanced background suppression power by anti-veto and PSD in this study and the GERDA experiment [2], we expect to have strong background suppression power in CDEX-300ν with LAr as the veto detector. Furthermore, the existing PPCGe detectors used in dark matter searches can be added into the detector array. Those PPCGe will serve as the detectors for$ {0\nu\beta\beta} $ while maintaining their ability to search dark matter and other new physics in the low energy region.Figure 12. (color online) CDEX-1B result of the effective Majorana neutrino mass. The green band and magenta band indicate the parameter space allowed by the inverted hierarchy (IH) and normal hierarchy (NH) as a function of the lightest neutrino mass
$m_{\rm light}$ , respectively [44]. The brown and blue bands denote the result from CDEX-1B (this work) and CDEX-1A experiments [10], respectively. The purple and yellow bands represent the final result of the GERDA and Majorana Demonstrator experiments, respectively [2, 9]. Currently, these two experiments hold leading positions in the 76Ge-based$ {0\nu\beta\beta} $ experiments. Furthermore, the projected sensitivity of CDEX-300ν is imposed. All the effective Majorana neutrino mass is calculated using the latest values of nuclear matrix element, 2.66–6.34 [4].The CDEX-300ν experiment is planned to realize a background level of
$ 1\times 10^{-4} $ counts/(keV$ \cdot $ kg$ \cdot $ yr), and it is expected to attain a half-life sensitivity of$ 3.3\times 10^{27} $ yr for 76Ge$ {0\nu\beta\beta} $ in 10 years of effective runtime, corresponding to the effective Majorana neutrino mass region of$ \langle m_{\beta\beta}\rangle < $ 18–43 meV (90% C.L.) (Fig. 12).
Searching for 76Ge neutrinoless double beta decay with the CDEX-1B experiment
- Received Date: 2023-09-19
- Available Online: 2024-10-15
Abstract: We operated a p-type point contact high purity germanium (PPCGe) detector (CDEX-1B, 1.008 kg) in the China Jinping Underground Laboratory (CJPL) for 500.3 days to search for neutrinoless double beta (