Time Measurement System Prototype for BESⅢ TOF

  • To meet the physics requirement, the time resolution of TOF (Time-of-flight) detector of the BESⅢ (Beijing Spectrometer Ⅲ) is required to be less than 90ps (rms), and the FEE (front end electronic) must contribute less than 25ps. This paper describes the prototype design of BESⅢ's TOF readout system (including time and amplitude measurement circuits).Preliminary results for prototypes of TOF front end electronics are given.
  • 加载中
  • [1] . BES Collaboration. The BES Upgrade. Nucl. Instrum.Methods, 2001, A458: 627-6372. Chen C, Jones M, Kononenko W et al. IEEE Transactionon Nuclear Science, 50(6): 2486-24903. Christiansen J, Marchioro A, Moreira P et al. Proceedings of the 6th Workshop on Electronics for LHC Experiments,20004. Joey Doernberg, LEE Hae-Seung, David A. Hodges, IEEEJournal of Solid-State Circuits, 1984, 19(6): 820-8275. LIU Shu-Bin, GUO Jian-Hua, ZHANG Yan-Li et al. Nu-clear Technology, 2006, 29(1): 72-76(in Chinese)(刘树彬,郭建华,张艳丽等.核技术,2006,29(1):72—76)6. Mantyniemi A, Rahkonen T, Kostamovaara J. Circuits and Systems, 2002 ISCAS 2002, 1: 513-5167. LI Jia-Cai, ZHANG Liang-Sheng, HU Chun-Liang et al.HEP NP, 2005, 29(1): 55-61(in Chinese)(李家才,张良生,胡春良等.高能物理与核物理,2005,29(1):55—61)
  • 加载中

Get Citation
GUO Jian-Hua, LIU Shu-Bin, ZHOU Shi-Long, LIU Xiao-Hua and AN Qi. Time Measurement System Prototype for BESⅢ TOF[J]. Chinese Physics C, 2006, 30(8): 761-766.
GUO Jian-Hua, LIU Shu-Bin, ZHOU Shi-Long, LIU Xiao-Hua and AN Qi. Time Measurement System Prototype for BESⅢ TOF[J]. Chinese Physics C, 2006, 30(8): 761-766. shu
Milestone
Received: 2005-11-24
Revised: 2006-02-13
Article Metric

Article Views(4545)
PDF Downloads(719)
Cited by(0)
Policy on re-use
To reuse of subscription content published by CPC, the users need to request permission from CPC, unless the content was published under an Open Access license which automatically permits that type of reuse.
通讯作者: 陈斌, bchen63@163.com
  • 1. 

    沈阳化工大学材料科学与工程学院 沈阳 110142

  1. 本站搜索
  2. 百度学术搜索
  3. 万方数据库搜索
  4. CNKI搜索

Email This Article

Title:
Email:

Time Measurement System Prototype for BESⅢ TOF

    Corresponding author: LIU Shu-Bin,
  • Fast Electronics Lab of Modern Physics Department of USTC, Hefei 230026, China

Abstract: To meet the physics requirement, the time resolution of TOF (Time-of-flight) detector of the BESⅢ (Beijing Spectrometer Ⅲ) is required to be less than 90ps (rms), and the FEE (front end electronic) must contribute less than 25ps. This paper describes the prototype design of BESⅢ's TOF readout system (including time and amplitude measurement circuits).Preliminary results for prototypes of TOF front end electronics are given.

    HTML

Reference (1)

目录

/

DownLoad:  Full-Size Img  PowerPoint
Return
Return