Neutrou Energy Response of a Modified Andersson-Braun Rem Counter from 0.025eV to 45.4MeV

  • This paper describes the principle and construction of a modified Andersson-Braun(A-B) neutron rem counter which is used for the stray radiation field of high energy accelerator. The energy responses from thermal neutron to 45.4MeV semi-monoenergetic neutron experiments with four kinds of A-B rem counter were carried out using a few of neutron generating facilitiest The response investigation of A-B rem counters for the stray radiation field outside shielding of 12 GeV proton accelerator was completed. The results show that in the high energy neutron radiation field, the response of modified A-B rem counters is better than that of conventional A-B rem counters.
  • 加载中
  • [1] Li Jianping, Tang Yueli, Liu Shudong et al. Radiation Protection Dosimetry, 1996, 67: 179[2] Moritz L. E., Suzuh T., Noguchi M. et al. Health Phys., 1990, 58:487[3] Jiang Wengui. Measurement of Neutron (Ei20MeV) Dose Equivalent Using the Ration of Carbon to Indium. 1n:Prceeding of the Third Symposium of Radiation Protection. 1995[4] ICRP. Data for Use in Protection Against Extemal Radiation. In: ICRP Publication 51. Oxford: Pergamon,1987. 17[5] Birattari C., Ferrari A,, Nuccer C. et al. Nucl. Instrum. Methods Phys. Res., 1990, A297:250[6] Birattari C., Esposito A,, Fenxi A. et al. Radiation Protection Dosimetry, 1992, 44: 193[7] Rai-Ko S.F.Sun. Modification of an Andenson-Braun Type Remrneter to Extend its Sensitivity to 400MeV. In: LBL-36436. 1994[8] Baba M., Iwasala T., Matsuyama S. et al. Development of Monoenergetic Neutron Calibration Field Between 8KeV and I5MeV. In: Fast Neutron Laboratory Progress Report. Tothby University: NETU-62, 1994[9] Nakamura T. et al. The Development of the Standard Calibration Method of Neutron Dosimeter for Widely Distributed Spectrum in the Energy. In: Report of Grant-in-Aid General(B) of the Japanese Ministry of Education, Culture and Science. 1992, 1993[10] Takada M. et al. Nucl. Instrum. Methods Phys. Res., 1991, A372:253 [11] Tanka S., Nukamura T. Shielding Experiments and Analysis at 90MV AVF Cyclotron Fasility. In: OECDDocuments. 1994. 195
  • 加载中

Get Citation
Tang Yueli, Li Jianping, Liu Shudong, Zhang Qingjiang and Cai Xiaoping. Neutrou Energy Response of a Modified Andersson-Braun Rem Counter from 0.025eV to 45.4MeV[J]. Chinese Physics C, 1998, 22(1): 78-86.
Tang Yueli, Li Jianping, Liu Shudong, Zhang Qingjiang and Cai Xiaoping. Neutrou Energy Response of a Modified Andersson-Braun Rem Counter from 0.025eV to 45.4MeV[J]. Chinese Physics C, 1998, 22(1): 78-86. shu
Milestone
Received: 1900-01-01
Revised: 1900-01-01
Article Metric

Article Views(2861)
PDF Downloads(607)
Cited by(0)
Policy on re-use
To reuse of subscription content published by CPC, the users need to request permission from CPC, unless the content was published under an Open Access license which automatically permits that type of reuse.
通讯作者: 陈斌, bchen63@163.com
  • 1. 

    沈阳化工大学材料科学与工程学院 沈阳 110142

  1. 本站搜索
  2. 百度学术搜索
  3. 万方数据库搜索
  4. CNKI搜索

Email This Article

Title:
Email:

Neutrou Energy Response of a Modified Andersson-Braun Rem Counter from 0.025eV to 45.4MeV

    Corresponding author: Tang Yueli,
  • Institute of High Energy Physics, The Chinese Academy of Sciences, Beijing 100039

Abstract: This paper describes the principle and construction of a modified Andersson-Braun(A-B) neutron rem counter which is used for the stray radiation field of high energy accelerator. The energy responses from thermal neutron to 45.4MeV semi-monoenergetic neutron experiments with four kinds of A-B rem counter were carried out using a few of neutron generating facilitiest The response investigation of A-B rem counters for the stray radiation field outside shielding of 12 GeV proton accelerator was completed. The results show that in the high energy neutron radiation field, the response of modified A-B rem counters is better than that of conventional A-B rem counters.