Abstract:
We investigated the nuclear counter effect of the silicon photodiode mounted on a CsI(Tl) crystal detector due to the leakage of electromagnetic shower through the rear end of the crystal. Using electron beams at IHEP, we have tested its effect on the energy measurement by the CsI(Tl) calorimeter for BESⅢ experiment. The results are found to be in good agreement with that of GEANT simulation and the effect for the BESⅢ calorimeter is negligible.
-
-
References
|
[1]
|
. Preliminary Design Report of the BES0 Detector InternalDocument, 2003. 119-133(in Chinese)(北京正负电子对撞机重大改造上程BEPC II初步设计BESIII探测器.2003. 119-133)2. Satpathy A, Tamai K, Fukushima M et al. Nuclear CounterE ect of Silicon PIN Photodiode Used in CsI(Tl) CalorimeterN.I.M in Physics Research, 1997, A391: 423-4263. XIA Xiao-Mi, WANG Man, LU Jun-Guang et al. TheStudy of Photodiode Read out for Scintillation CrystalCalorimeter.In: Academy of Nuclear Electronics NuclearDetection Technology ed. Proceedings of the 11th NationalConference on Nuclear Electronics Nuclear DetectionTechnology. 2002. 231-235(in Chinese)(夏小米,王曼,吕军光等.闪烁晶体量能器用硅光一级管读出的研究.见:中国电子学会、中国核学会、核电子学与核探测技术分会编辑.第11届个国核电子学与核探测器学术年会论文集,2002. 231-235)4. CUI Xiang-Zong, LI Jia-Cai et al. HEP NP, 2004, 28(8):870-876(in Chinese)(崔象宗,李家才等.高能物理与核物理,2004, 28(8): 870-876)5. LIU Chun-Xiu. The Monte-Carlo Simulation Study of theBES0 Crystal Calorimeter. In: Institute of High EnergyPhysics, Chinese Academy of Sciences ed. The PostdoctoralStudy Report of Institute of High Energy Physics,Chinese Academy of Sciences. 2003. 1-52(in Chinese)(刘春秀.BES川晶体量能器的蒙特片罗模拟研究.见:中国科学院高能物理研究所(北京)编辑.中国科学院高能物理研究所博士后研究上作报告.2003. 1-52)
|
-
-