PAD Design for the Phasing System of BEPCⅡ Linac
- Received Date: 2005-05-30
- Accepted Date: 1900-01-01
- Available Online: 2006-02-05
Abstract: Phase and amplitude measurement is one of the most important issues for the phasing system of BEPCⅡ linac. Two kinds of PAD, based on analog and digital I/Q demodulator respectively, have been constructed and tested in both laboratory and the klystron gallery of BEPCⅡ linac. A calibration algorithm based on LMS method is used to compensate the mismatches of the analog I/Q demodulator. Experiments show that both kinds of PAD run stably and can meet the requirements of the phasing system.