Abstract:
The pulse shape and the intensity of Cerenkov light from extensive air shower have been recorded by using two different types of photomultipliers (fast and slow).The distribution of the FWHM of Cerenkov light pulse and the spectrum of Cerenkov photo density have been measured for E>5×1014eV,at sea level.Comparing the two intensity results from two types of tubes indicate that the system which consists of the slow tubes and the peak ADC is not only simple but also cheap for the Cerenkov light intensity measurement.
-
-
References
|
[1]
|
A. M. Hilias, J. Phys. G: Nucl. Phys., 8(1982), 1475.[2] M. P. Chanrler et al., J . Phys. G: Nucl. Phys., 9(1983). L27.[3] De. Jager et al., "The Design And Evaluation of A 1Tev Gamma Ray Telserope" (1985).[4] R. W. Clay et al., Aust. J. Phys., 36(1983), 227.[5] N. lnoue et al., J. Phys. G: Nucl. Phys., 11(1985), 657.[6] J. R. Patterson and A. M. Hillas., J. Phys. G: Nucl. Phys., 9(1983), 1433.[7] D. F. Liebing et al., J. Phys. G: Nucl. Phys., 10(1984). 1283.[8] 李延国等:核电子学与探测技术,7(1987), 342.[9] T. Hara et al., 15th lCRC, 8(1977), 308.[10] G. J. Thornton and R. W. Clay., J. Phys. G: Nucl. Phys., 4(1978), L193.[11] T. J. L. McComb , and K. E. Turver, Nuov Gim., 5C( 1982), 181.[12] J . V. Jelley., "Progress in Elementary Particle and Cosmic Ray Physics", Vol. 1X (1967), p. 83-85.[13] R. J. Prothrroe and J. R. Patterson, J . Phys. G: Nucl. Phys, 10(1984), 841.[14] R. J . Protheroe and K. E. Turver., Nuov Cim., 51A(1979), 277.[15] A. A. Andarn et al, 17th lCRC (Paris), 6(1981), 125.[16] T. A. Alimov et al., 18th ICRC (Bangalore), 11(1983). 387.[17] N. N. Kalmykov et al., 18th ICRC (Bangalorr), 11(1983), 383.
|
-
-