Abstract:
The principle of beam position monitoring of button was introduced briefly. It was compared with beam bugs in principle. Based on the result in simulation experiment, a new structure of button was design, and some mistakes in the primary design was correctted. In the realy beam experiment of “Dragon Ⅰ”, the beam waveform and position were monitored. Compared the position curve between button and beam bugs, that indicated the data that got form button is credible. In the experiment, the button have an accuracy of 0.5mm, which is adequate for beam position measurement of “Dragon Ⅰ”.
-
-
References
|
[1]
|
. SHI Jin-Shui. Corkscrew Motion and Its Prevention in Lin-ear Induction Electron Accelerator. Engineering Doctor pa-per of Tsinghua University, 2002(in Chinese)(石金水.直线感应电f加速器中的Corkscrew运动及抑制.清华大学上学博士学位论文,2002)2. MA Li, SHI Ping. Upgrade of the BPM System for theBEPC Storage Ring. Proceeding of 1998. IEEE, 80(4):2075-20773. Hinode F. A Conventional Read-Out Electronics for theButton-Type BPM in the ATF Damping Ring. Proceedingof 1998. IEEE, 80(2): 578-5804. Tsumoru Shintake, Masaki Tejima. Sensitive Calculation ofBeam Positon Monitor Using Boundary Element Method.Nuclear Instruments and Methods, 1987, A254: 146-1505. Pai S T, ZHANG Qi. Introduction to High Power PulseTechnology. Singapore: World Scienti c, 1998. 102-1036. XU Tie-Zheng, WANG Hua-Cen, XIE Yu-Tong et al. HighPowar Laser and Paticle Beams, 2004, 16(1): 91(in Chinese)(徐铁铮,王华岑,谢宇彤等.强激光与粒子束,2004, 16(1):91)
|
-
-