Data Offline Calibration for the BES-Ⅱ TOF System

  • Data offline calibration and reconstruction for the BES-Ⅱ TOF system are reported in this paper. After applying calibration constants to correct the measured raw data, a the resolution of 180 ps is obtained for the new TOF system. The power of charged particle identification is improved. The momentum for the 3σπ/K separation goes up to 0.93 GeV/c.
  • 加载中
  • [1] BAI Jing–Zhi et al (BES Collaboration). BES Upgrade, N. I. M., to be submitted 2 MAO Ze–Pu et al. HEP NP, 1996, 20:1073–1081(in Chinese)(毛泽普等. 高能物理与核物理,1996,20:1073—1081)3 RONG Gang. Status of BES–Ⅱ TOF Data (Spring 1998) Offline Calibration and Reconstruction. In: Procedings ofthe 7th BES Annual Meeting. 17–19 June 1998, Datong, BES –Ⅱ TOF Data Offline Calibration, BES–Ⅱ Note,June, 1996
  • 加载中

Get Citation
RONG Gang, ZHAO Jia-Wei, LIU Qi, XUE Sheng-Tian, CHEN Guang-Pei, LI Pei-Qin, LIU Jing, MAO Ze-Pu, LI Wei-Guo, QIU Jin-Fa, XU Chun-Cheng, XIE Yue-Hong, YUAN Ye and ZHAO Hai-Wen. Data Offline Calibration for the BES-Ⅱ TOF System[J]. Chinese Physics C, 2001, 25(2): 154-159.
RONG Gang, ZHAO Jia-Wei, LIU Qi, XUE Sheng-Tian, CHEN Guang-Pei, LI Pei-Qin, LIU Jing, MAO Ze-Pu, LI Wei-Guo, QIU Jin-Fa, XU Chun-Cheng, XIE Yue-Hong, YUAN Ye and ZHAO Hai-Wen. Data Offline Calibration for the BES-Ⅱ TOF System[J]. Chinese Physics C, 2001, 25(2): 154-159. shu
Milestone
Received: 2000-02-12
Revised: 1900-01-01
Article Metric

Article Views(3699)
PDF Downloads(758)
Cited by(0)
Policy on re-use
To reuse of subscription content published by CPC, the users need to request permission from CPC, unless the content was published under an Open Access license which automatically permits that type of reuse.
通讯作者: 陈斌, bchen63@163.com
  • 1. 

    沈阳化工大学材料科学与工程学院 沈阳 110142

  1. 本站搜索
  2. 百度学术搜索
  3. 万方数据库搜索
  4. CNKI搜索

Email This Article

Title:
Email:

Data Offline Calibration for the BES-Ⅱ TOF System

    Corresponding author: RONG Gang,
  • Institute of High Energy Physics, CAS, 100039 Beijing, China1 Department of Modern Physics, University of Science and Technology of Chins, Hefei 230026, China

Abstract: Data offline calibration and reconstruction for the BES-Ⅱ TOF system are reported in this paper. After applying calibration constants to correct the measured raw data, a the resolution of 180 ps is obtained for the new TOF system. The power of charged particle identification is improved. The momentum for the 3σπ/K separation goes up to 0.93 GeV/c.

    HTML

Reference (1)

目录

/

DownLoad:  Full-Size Img  PowerPoint
Return
Return