High-Power Test of Iris Coating in the S-Band Linear Collider

  • The excitation of Higher, Order Modes (HOM) in an accelerator can lead to cumulative beam break up, therefore, these modes have to be suppressed. For the S-Band Linear Collider (SBLC), it has been suggested to cover the disk loaded strucks at the iris with an aPPropriate loss malarial. For the high-power test of the iris coating a resonator consishng of tWo cells of the SBLC is used. This paper describes the high-power test and gives some Preliminary results.
  • 加载中
  • [1] Dehlus M et al. Higher Order Mode Daming by Artificially Increased Surface Losses, DESY Repoty to be Published2 Haimson J. Collinear Termination for High–Energy Particle Accelerators, PATENT–US–3264515, Aug. 19663 Holtkamp N. For the SBLC Study Group, The S–Band Linear Collider Test Facility, PAC 95, Dallas, May lth–5th, 1995 4 Wilson P B. SLED: A Method for bobling SLACs Energy, Tactical Note SIAC–TN–73–15, Stanford Linear Accelebor Center, Stanford University, Stanford, California, 1973
  • 加载中

Get Citation
Jin Kai. High-Power Test of Iris Coating in the S-Band Linear Collider[J]. Chinese Physics C, 1999, 23(9): 931-935.
Jin Kai. High-Power Test of Iris Coating in the S-Band Linear Collider[J]. Chinese Physics C, 1999, 23(9): 931-935. shu
Milestone
Received: 1999-03-05
Revised: 1900-01-01
Article Metric

Article Views(3438)
PDF Downloads(640)
Cited by(0)
Policy on re-use
To reuse of subscription content published by CPC, the users need to request permission from CPC, unless the content was published under an Open Access license which automatically permits that type of reuse.
通讯作者: 陈斌, bchen63@163.com
  • 1. 

    沈阳化工大学材料科学与工程学院 沈阳 110142

  1. 本站搜索
  2. 百度学术搜索
  3. 万方数据库搜索
  4. CNKI搜索

Email This Article

Title:
Email:

High-Power Test of Iris Coating in the S-Band Linear Collider

    Corresponding author: Jin Kai,
  • National Synchrotron Radiation Laboratory, USTC NSTC Hefei 2300292 Deutsches Eleforonen-Synchrotron DESY,Hamburg 22607, Germany3 Moscow Engineering Physics Institute MEPhI, Moscow 115409, Russia4 Institute of Nuclear INR, Moscow 117312, Russia

Abstract: The excitation of Higher, Order Modes (HOM) in an accelerator can lead to cumulative beam break up, therefore, these modes have to be suppressed. For the S-Band Linear Collider (SBLC), it has been suggested to cover the disk loaded strucks at the iris with an aPPropriate loss malarial. For the high-power test of the iris coating a resonator consishng of tWo cells of the SBLC is used. This paper describes the high-power test and gives some Preliminary results.