INVESTIGATION OF SATURATED AVALANCHE AND SELF-QUENCHING STREAMER DISCHARGE MODES
- Received Date: 1900-01-01
- Accepted Date: 1900-01-01
- Available Online: 1983-12-05
Abstract: To investigate the possibilities of the self-quenching streamer mode (SQS) and saturated avalanche mode (SA) as the sampling means in the gas shower sampling calorimeter, this article reports the systematic measurements on gas multiplication characteristics from the proportional region to SQS region under several different mixture proportions of argon + methene, argon+ethene, argon+isobutane and argon+carbon dioxide mixtures, it also presents Several SQS counting plateaus. It is shown that if the proportion of the quenching gas is above 50% we can get about 300—400 volts SQS optimum operation region, in which almost all of the SA signals transit to SQS mode and the second leap of the SQS amplitude have not-occured, this is a very promising region for sampling counters in gas sampling calorimeter.