Abstract:
A prototype multi-gap resistive plate chamber (MRPC) with a 2×6 gap structure is developed for the upgrading of the endcap time-of-flight (ETOF) detector in the Beijing Spectrometer (BESⅢ). The prototype MRPC is tested in the E3 beam line of the Beijing Electron Positron Collider (BEPC) with secondary charged particles (π and p, etc) of 600 MeV/c. The test results show that the time resolution of the MRPC can reach 50 ps and that the detection efficiency is greater than 98%.
-
-
References
|
[1]
|
ZHAO Chuan, SUN Sheng-Sen et al. Chinese Physics C (HEP NP), 2011, 35(1): 722 Williams M C S, Cerron E et al. Nucl. Instrum. Methods A, 1999, 434(2-3): 3623 CHEN Hong-Fang, LI Cheng et al. High Energy Physics and Nuclear Physics, 2002, 26(3): 201 (in Chinese)4 WU Jian, Bonner B et al. Nucl. Instrum. Methods A, 2005,538: 2435 ALICE Time of Flight Addendum. CERN/LHCC 2002-016, Addendum to ALICE TDR 8, 24 April 20026 LI Cheng, CHEN Hong-Fang et al. High Energy Physics and Nuclear Physics, 2002, 26(5): 455 (in Chinese)7 SHAO Ming, CHEN Hong-Fang et al. High Energy Physics and Nuclear Physics, 2004, 28(7): 733 (in Chinese)8 LI Jia-Cai, WU Yuan-Ming et al. High Energy Physics and Nuclear Physics, 2004, 28(12): 1269 (in Chinese)9 LI Liang, SHAO Ming et al. High Energy Physics and Nu- clear Physics, 2007, 31(6): 576 (in Chinese) |
-
-
Access
-
-