MONTE-CARLO CALCULATION ON ACHIEVABLE ACCURACY OF TAU LIFETIME MEASUREMENT BY USING TEC TYPE VERTEX CHAMBER IN e+e INTERACTION AT CENTER OF MASS ENERGY √s =40GeV

  • The most accurate tau lifetime measurement in e+e experiments by now is reported by MARK Ⅱ with the value (3.20±0.41±0.35)×10-13 sec. wherein the second and the third terms are statistical and systematic errors respectively. By using TEC (Time Expansion Chamber) type vertex chamber with position resolution 40μ in r-φ plane at similar experimental condition (∫Ldt=40pb-1), MONTE-CARLO calculation shows: at center of mass energy √s =40GeV the statistical error of tau lifetime can be decreased to 0.13×10-13 sec. and the systematic error is in a comparable value.
  • 加载中
  • [1] C. A. Blocker et al., Phys. lett., 109B, (1982), 119.[2] X. LI and E. MA, Phys. Rev. Lett., 47, (1981), 1788, D. Miller, Phys. Rev., D23, (1981), 1158. G. L. Kane, SLAC-PUB-2326 (1979);D. Miller, SLAC-PUB-2713 (1981 ).[3] J. Jaros SLAC-PUB-3044 (1983);J. Jaros et al., SLAC-PUB-3164 (1983).[4] H. J. Behrend et al., DESY 82-056 (1982).[5] R. Brandelik et al., Phys. Lett., 92B, (198G), 199.[6] W. T. Ford et al., SLAC-PUB-2913 (1982).[7] G. J. Feldman et al., Phys. Rev. Lett., 48,(1982),66.[8] A. H. Walenta. IEEE Trans. Nucl. Sci. NS-26, Nr. 1,(1979),73.[9] A. H. Walenta et al., Inter. Conf. on Instrumentation for Colliding Beam Physics, 1982, SLAC Stanford, California.
  • 加载中

Get Citation
ZHU Yong-Sheng. MONTE-CARLO CALCULATION ON ACHIEVABLE ACCURACY OF TAU LIFETIME MEASUREMENT BY USING TEC TYPE VERTEX CHAMBER IN e+e INTERACTION AT CENTER OF MASS ENERGY √s =40GeV[J]. Chinese Physics C, 1984, 8(5): 513-522.
ZHU Yong-Sheng. MONTE-CARLO CALCULATION ON ACHIEVABLE ACCURACY OF TAU LIFETIME MEASUREMENT BY USING TEC TYPE VERTEX CHAMBER IN e+e INTERACTION AT CENTER OF MASS ENERGY √s =40GeV[J]. Chinese Physics C, 1984, 8(5): 513-522. shu
Milestone
Received: 1900-01-01
Revised: 1900-01-01
Article Metric

Article Views(2298)
PDF Downloads(453)
Cited by(0)
Policy on re-use
To reuse of subscription content published by CPC, the users need to request permission from CPC, unless the content was published under an Open Access license which automatically permits that type of reuse.
通讯作者: 陈斌, bchen63@163.com
  • 1. 

    沈阳化工大学材料科学与工程学院 沈阳 110142

  1. 本站搜索
  2. 百度学术搜索
  3. 万方数据库搜索
  4. CNKI搜索

Email This Article

Title:
Email:

MONTE-CARLO CALCULATION ON ACHIEVABLE ACCURACY OF TAU LIFETIME MEASUREMENT BY USING TEC TYPE VERTEX CHAMBER IN e+e INTERACTION AT CENTER OF MASS ENERGY √s =40GeV

    Corresponding author: ZHU Yong-Sheng,
  • Institute of High Energy Physics, Academia Sinica

Abstract: The most accurate tau lifetime measurement in e+e experiments by now is reported by MARK Ⅱ with the value (3.20±0.41±0.35)×10-13 sec. wherein the second and the third terms are statistical and systematic errors respectively. By using TEC (Time Expansion Chamber) type vertex chamber with position resolution 40μ in r-φ plane at similar experimental condition (∫Ldt=40pb-1), MONTE-CARLO calculation shows: at center of mass energy √s =40GeV the statistical error of tau lifetime can be decreased to 0.13×10-13 sec. and the systematic error is in a comparable value.

    HTML

Reference (1)

目录

/

DownLoad:  Full-Size Img  PowerPoint
Return
Return